Controller functions
Version 1
RES-408
Page 51
11.19 Diagnostic interface / visualization software (as of June 2006)
An interface with a 6-pole Western socket is provided for system diagnostics and process visualization. This inter-
face allows a data connection to be set up to the ROPEX visualization software using the ROPEX CI-USB-1 com-
munication interface.
Only a ROPEX communication interface is allowed to be connected to the diagnostic interface. Con-
necting another device (e.g. a telephone cable) could result in malfunctions or damage to the con-
troller.
The ROPEX visualization software is described in a separate document.
11.20 System monitoring / alarm output
To increase operating safety and avoid faulty heatsealing, this controller incorporates special hardware and soft-
ware features that facilitate fault diagnosis and selective error messages. Both the external wiring and the internal
system are monitored.
These features crucially support the system owner in localizing the cause of an abnormal operating state.
A system fault is reported or differentiated by means of the following indications:
A.)
Error message on the terminal display:
The cause of a fault can be localized quickly and easily with the help of the error code that appears on the display.
Please refer to section 11.21 "Error messages" on page 52 for a list of possible error codes.
B.)
Controllers manufactured as of June 2006:
Red "ALARM" LED on the controller with
three states:
1.
Blinking fast (4Hz)
The "AUTOCAL" function should be executed (error codes 104…106, 211, 302, 303).
2.
Blinking slowly (1Hz)
The system configuration is incorrect and the zero calibration (AUTOCAL function) was therefore unsuccessful
(
section 10.2 "Controller configuration" on page 25). This corresponds to error codes 111…114.
3.
Lit continuously: