Controller functions
Page 44
RES-408
Version 1
trollers manufactured up to December 2000, the same effect can be achieved by pressing the "HAND" key in the
"HA" [
HA
nd] step.
11.11
Hold mode
The behavior of the ACTUAL temperature display in the home position can be changed with the "HO" [
HO
ld] step.
The following settings are possible:
1.
"OFF" (Factory setting)
If the home position is visible on the display, the real ACTUAL temperature is always indicated.
2.
"On"
If the display is in the home position, the ACTUAL temperature that was valid at the end of the last heatsealing
phase is always indicated as a digital value. When the controller is powered up, the real ACTUAL temperature
is shown until the end of the first heating phase.
3.
"On2"
This setting is available on controllers manufactured as of June 2006.
It causes the current ACTUAL temperature to be displayed for an additional 2 seconds at the end of a heat-
sealing phase. This temperature is then indicated again in real time until the end of the next heatsealing phase.
Hold mode only affects the value on the display. The ACTUAL temperature is always indicated in
real time, regardless of the setting, at the actual value output.
!