R O P E X
R O P E X
R O P E X
R O P E X
INDUSTRIE - ELEKTRONIK GmbH
Page 6
Relay K1 will activate concurrently with the
start signal to the controller, and release after
The heating cycle time begins with the start
Relay K1 will activate when the heatseal band
reaches the pre-set temperature, and release
after the cooling cycle times out.
The heating cycle starting time begins when
the heatseal band reaches the pre-set
temperature.
Relay K1 activates to produce a "signal pulse"
( .5 sec.) after the completion of the cooling
cycle.
Relay K1 activates concurrently with the start
signal to the controller and releases when the
preset cooling temperature of the heatseal
band has been reached.
Relay K1 will activate when the heatseal band
reaches the pre-set temperature, and release
after the pre-set cooling temperature has
been reached.
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
A
F
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
B
G
1 2 3 4 5 6 7 8 9 10
ON
C
1 2 3 4 5 6 7 8 9 10
ON
D
1 2 3 4 5 6 7 8 9 10
ON
E
1 2 3 4 5 6 7 8 9 10
ON
H
4.1 PROGRAMMING THE OUTPUT RELAY
tK = Cooling Time
tH = Heating Time
K1 = Relay
4.2 PROGRAMMING THE HEATING TIME
4.3 PROGRAMMING FOR CONSTANT HEAT
At the initial start signal the controller will be
activated to heat and control the heatseal
band temperature until the power supply to
the controller is disabled. The K1 timer
sequence is independent of this and can be
START
TEMP
K1
K1
K1
K1
K1
tH
tH
TEMP
TIME
tH
tK
0,5
4. TIMING FUNCTIONS PROGRAMMING
(LED: Green )
(LED: Red )
(LED: Yellow)
The output relay may be programmed for 5 different modes of timing sequence,
for activating the seal jaws or other functions, by setting the DIP switches on the
side of the controller.
The heating time can be programmed for 2 different modes by using the DIP
switches on the side of the controller.