Controller functions
Page 28
RES-430
10.2.2 Display in home position
If no settings are entered on the controller and no alarm
signals are present, the display is in the home position,
in other words it indicates the SET temperature as a
digital value and the ACTUAL temperature as a digital
value and a dynamic bar.
10.2.3 Settings/Configuration menus
The required parameters are set on two menu levels:
the Settings (control) menu and the Configuration
menu (
ª
section 10.4 "Menu structure" on page 31).
10.2.4 Alarm signals
The fault diagnosis function of the controller is always
active. If a fault is detected, it is indicated on the display
immediately in the form of an alarm signal
(
ª
section 10.18 "System monitoring / alarm output" on
Icon indicates that NO
contact of additional
Specified heatsealing
temperature
(SET temperature)
relay K1 is closed
Measured ACTUAL
temperature
ACTUAL temperature
as a dynamic bar
Heatsealing
parameters
Cooling
parameters
Menu level:
Settings or Configuration menu
(Configuration menu shown here)
Position in menu
(menu step)
Menu contents
(max. 3 lines)
Alarm indication
Fault description
and error code
Prompt to press
"RESET" key