Application
4
UPT-640 (as of SW 100)
1.6
Standards / CE marking
The controller described here complies with the
following standards, provisions and directives:
Compliance with these standards and provisions is only
guaranteed if original accessories and/or peripheral
components approved by ROPEX are used. If not, then
the equipment is operated on the user's own
responsibility.
The CE marking on the controller confirms that the
device itself complies with the above-mentioned
standards.
It does not imply, however, that the overall system also
fulfils these standards.
It is the responsibility of the machine manufacturer and
of the user to verify the completely installed, wired and
operationally ready system in the machine with regard
to its conformity with the safety provisions and the EMC
directive (see also section 8.3, "Power supply"). If
peripheral components (e.g. the transformer or the line
filter) from other manufacturers are used, no functional
guarantee can be provided by ROPEX.
1.7
Warranty provisions
The statutory provisions for warranties apply for a
period of 12 months following the delivery date.
All devices are tested and calibrated in the factory.
Devices that have been damaged due to faulty
connections, dropping, electrical overloading, natural
wear, incorrect or negligent handling, chemical
influences or mechanical overloading as well as
devices that have been modified, relabeled or
otherwise altered by the customer, for example in an
attempt to repair them or install additional components,
are excluded from the warranty.
Warranty claims must be examined in the factory and
approved by ROPEX.
2
Application
This CIRUS temperature controller is an integral part of
the "series 600". Its sole purpose is to control the tem-
perature of CIRUS/UPT heating elements, which are
used mainly for impulse-heatsealing PP and PE films.
The most important applications are packaging
machines, pouch-making machines, splicers,
machines for making pharmaceutical and medical pro-
ducts etc.
DIN EN 61010-1:2001
(2006/95/EG)
Safety requirements for electrical
equipment for measurement,
control and laboratory use
(low-voltage directive):
pollution degree 2,
protection class II,
measurement category I
(for U
R
and I
R
terminals)
DIN EN 60204-1
(2006/42/EG)
Electrical equipment of
machines (machinery directive)
EN 55011:1998 + A1:1999 +
A2:2002
EN 61000-3-2:2006-04
EN 61000-3-3:1995-01 +
A1:2001 + A2:2005-11
(2004/108/EG)
EMC genery emissions:
Group 1, Class A
EN 61000-6-2:2005
(2004/108/EG)
EMC generic immunity:
Class A (ESDs, RF radiation,
bursts, surges)
Exception:
Line voltage interruption acc.
EN 61000-4-11 is not fulfilled
(This leads to a designated error
message of the controller)