18. On the rear of the handle is a handle stop that sits
against the right hand side of the valve temperature stop
ring to prevent the handle being rotated past the pre-
determined maximum temperature position. Without moving
the temperature spindle, position the handle onto the
cartridge so that it cannot rotate anti-clockwise.
Note: Do NOT remove the temperature stop ring to make
adjustments as this will prevent correct assembly later.
Figure 16
Figure 17
You are now ready to set the maximum temperature of the valve.
17. With both outlet buttons checked for smooth operation, using a thermometer, test the temperature
of the water from the outlets. Rotate the cartridge spindle anti-clockwise to increase the temperature
and clockwise to reduce the temperature until the water from the outlet reaches the maximum
recommended temperature of 44ºC. Leave the cartridge in this position.
Temperature Stop Ring
Handle Stop