Battery Specifications:

Type - Lead Acid
Volts - 12V/96Ah
No of batteries - 2 per machine

Charger Specifications:

Charger Specifications:

Type - On Board 
Rating - 20 Amps

Type - Off Board 
Rating - 30 Amps

Disposal of Batteries

Old  batteries  with  this  sign  are  recyclable  economic 
goods  and  should  be  brought  back  into  the  recycling 
process.

Old  batteries  which  are  not  brought  back  into  the 
recycling process, have to be dealt with as dangerous 
materials under the observance of all regulations.

Dead-man’s Switch

Driving speed control

Direction Switch

TRACTION DRIVE

The machine is provided with a continuously adjustable 
traction drive. The driving speed, driving direction and 
dynamic  deceleration  are  controlled  by  the  electronic 
drive control. 

If the dead-man’s switch is released during operation, 
the  traction  drive  is  switched  off.  The  suction  turbine 
remains switched on. 

The driving speed control is a continuously adjustable 
knob to set the machine speed. 

The  direction  switch  is  used  to  preselect  the  driving 
direction of the machine. 
Switch to front - forward drive 
Switch to rear - reverse drive 
To change the driving direction, bring the machine to a 
complete stop, select the new direction and start again.  

Reduce speed while turning in corners or in slope.
DO NOT park the machine on a slope.
DO NOT DRIVE IN FLOODED AREAS. 

DO  NOT  THROW  THE  CHARGER  AND  THE 
BATTERIES ALONG WITH OTHER WASTE.

DO  NOT  THROW  THE  CHARGER  AND  THE 
BATTERIES INTO THE ENVIRONMENT.

BATTERY & CHARGER INSTRUCTIONS

NOTE:

 For more information about the charger kindly 

refer the charger manufacturer’s user manual which is 
supplied along with the machine.

Summary of Contents for BT4545

Page 1: ...otsScrub BT Series Owner s Manual RootsScrub BT Series Walk Behind Scrubber Drier w Traction Battery Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion...

Page 2: ...2 RootsScrub BT Series...

Page 3: ...General Safety Instructions First Operation Operation Brush Operation Squeegee Procedure for scrubbing Maintenance Battery Instructions 4 5 6 8 10 13 14 15 17 20 Roots Multiclean Ltd RMCL is not liabl...

Page 4: ...icy is applicable only for the product sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service c...

Page 5: ...Disc Type with Parabolic Squeegee BT 6050C Cylindrical Deck with Straight Squeegee BT 45 Series BT 60 Series BT 4545 Disc Type with Parabolic Squeegee BT 4545 Disc Type with Straight Squeegee BT 4550...

Page 6: ...087 1087 Power supply V 24 24 24 24 Total power W 1200 1200 1200 1200 Brush motor power W 720 720 650 720 Vacuum motor power W A 420 18 370 18 370 15 4 420 18 Drive motor TRACTION power W A 240 10 200...

Page 7: ...re mm of H2O 1224 1087 1087 Power Supply V 24 24 24 Total Power W 1200 1200 1200 Brush Motor W A 720 650 27 720 Vacuum Motor power W A 420 18 420 18 420 18 Drive Motor TRACTION power W A 200 10 200 10...

Page 8: ...miliarize themselves with all accessories and controls as well as their functions before commencing operation Adherence to the above general instructions will help avoid the operator from having to re...

Page 9: ...the frame sections Damaged parts may only be changed at an authorized service center It is not permitted to use aggressive and corrosive cleaning agents Used batteries with the recycling symbol must...

Page 10: ...is necessary to sweep the floor This way not only is the cleaning efficiency improved but wear of the brush is also substantially reduced If floors are particularly dirty or if wax has to be removed b...

Page 11: ...tus Brush motor suction turbine On Off Total hours run H LED Glows Green when power is On I LED Glows Red when there is a fault in the traction drive G Display LEGEND DESCRIPTION PURPOSE A Main Power...

Page 12: ...d the suction turbine shuts down after a delay of 15 seconds 0016 10 BATTERY CHARGING 6 The brush motor suction turbine icons will start flashing just before the battery cut off level 0016 10 8 Fully...

Page 13: ...ush head from being pressed down Removal of brush Empty the tanks Lift the squeegee and the brush head P r e s s s w i t c h D 1 D 2 simultaneously for unlocking of brush Press the rear end of the mac...

Page 14: ...foreign matter and for proper condition Mounting of Squeegee first time Lift squeegee bracket group 3 Mount squeegee 1 to squeegee bracket group 3 and screw the knobs 2 as shown in figure Attach suct...

Page 15: ...the work to be done through the filter which is present in front of the machine and add detergent as specified by the manufacturer Filling amount 45 45 Series 60 60 Series liters Max max 50 C Max wat...

Page 16: ...r is in top position The water flow is minimum or to stop when the lever is in bottom position For BT4545 BT4550 BT6050 Press D1 to start water supply from the solenoid valve to the brush head For BT4...

Page 17: ...the certitude always having a machine at your disposal which is ready to work and in good operating condition Daily Every 50 Every 100 Every 200 Check connection extension cables and plugs for good c...

Page 18: ...battery Loose battery cable Tighten loose cable Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not work Faulty suction turbine switch Replace...

Page 19: ...ew minutes and check motor consumption A6 POWER STAGE 6 Controller s power stage damaged Change the controller A7 OVERCURRENT 7 Overcurrent short circuit Check the motor s wires A8 POWER FUSE RELAY 8...

Page 20: ...ventilated area Make sure to connect the charger to the specified voltage and frequency Ensure that the seat cover is completely open Do not place any objects on the battery Electrolyte is highly cor...

Page 21: ...Keep the machine tank opened while charging to improve ventilation Battery and Charger Battery connecting diagram The batteries are located in the fresh water tank The On board charger is located in t...

Page 22: ...rolled by the electronic drive control If the dead man s switch is released during operation the traction drive is switched off The suction turbine remains switched on The driving speed control is a c...

Page 23: ...23 RootsScrub BT Series...

Page 24: ...RootsScrub BT Series Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 7...

Reviews: