background image

LASER DISTANCE METER

8

on screen.

.

INDIRECTLY HEIGHT I, II & III MEASUREMENT (BASE ON 

PYTHAGOREAN)

1) Click

thrice, four and five times to enable Indirectly Measurement.

2) Laser will be activated when entering indirectly measurement 
mode.
3) Follow the instructions on main screen to measure the LENGTH 
OF HYPOTENUSE(S) and BASE.

4) After finish all the instructions, the result [HEIGHT] will be showed 

on screen.

Indirect measure I
Indirect measure II
Indirect measure III  

ERROR CODE 

Code

Description

Solution

Error 01

Out of measuring range 

Measuring in a prop-
er range

Error 02

Reflected signal is too 

weak 

Select a better 
surface 

Error 03  Out of display range 

(Max Value: 99999), 
e.g.: result of area or di-
mension is out of display 
range

Divide calculation 
into intermediate 
steps

Error 04

Pythagorean calculation 
error

Check and verify 
values and steps are 
correct

Error 06  Out of working tempera-

ture

Measure in an 
environment within 

specified working 

temperature

Error 07

Ambient light is too 
strong

Measure in a darker 
place (Shadow 
target)

Summary of Contents for RH-9150T

Page 1: ...LASER DISTANCE METER RH 9150T...

Page 2: ...Unit Dimensions mm 105 41 24 mm Power Source 2 x AAA Batteries Measuring Unit m in ft ft in Storage Temperature 20 Cto 60 C Operating Temperature 5 Cto 40 C Dimensions 113 47 5 30 2 Battery Life 10 00...

Page 3: ...stance meter x 1 2 AAA Battery x 2 3 Operation manual x 1 4 Carrying case x 1 5 Safety strap x 1 SAFETY INFORMATION This is a Class 2 laser tool laser radiation is emitted from this product and is man...

Page 4: ...2 Indirect measuring 3 Measuring function 4 Measuring reference 5 Add and Subtract 6 Maximum display 7 Minimum display 8 Staked direction indicator 9 Main Screen and units 10 Countdown measuring 11 Me...

Page 5: ...e and get ready to measure by turn on the laser dot 3 Tap and hold for 3 seconds to turn off NOTE The device will turn off automatically after 180 seconds 3 minutes MEASURING STARTING POINTS On the bo...

Page 6: ...ferred unit 3 Unit Switch Reference Meter Feet Inch 0 0 1 32 Inch Inch Inch Length m ft in 0 0 1 32 1 32in 1 16in 1 8in 10 33 Area m ft ft ft ft ft ft P Volume m ft ft ft ft ft ft m BACKLIGHT LASER PO...

Page 7: ...stance and its multiplies COUNTDOWN MEASURE 1 For a more stable measurement or you could use countdown mea sure function to trigger measuring in setting times 2 Click to set your preferred self trigge...

Page 8: ...1 To make summary or difference between two measurements is easy 2 Finish your first measurement then click to save as Addend or to save as Minuend 3 Take the second measurement then click to add from...

Page 9: ...I Indirect measure II Indirect measure III ERROR CODE Code Description Solution Error 01 Out of measuring range Measuring in a prop er range Error 02 Reflected signal is too weak Select a better surf...

Page 10: ...ce in water Never use aggressive cleaning agents or solvents RECYCLING Batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided i...

Page 11: ......

Reviews: