background image

AIR COMPRESSOR

20

NOTE: 

Avoid refilling with too much oil. Ensure that the level of the oil does 

not exceed the top of the red dot at sight glass. The recommended 

amount of oil for refilling is 250ml.
1) Tighten the   cap securely into the fill hole.

.

ENVIRONMENTAL PROTECTION

Recycle raw materials instead of disposing of as waste. The 
machine, accessories and packaging should be sorted for envi-
ronmental-friendly recycling.

.

TROUBLESHOOTING

PROBLM

CAUSE

POSSIBLE SOLUTION

Compressor will not run

Loss of power or overheating

Check for proper use of 
extension cord

NO electrical power

Check to be sure unit is 
plugged in

Blown shop/house fuse

Check fuse/ breaker

Shop/house breaker open

Replace shop/house blow 
fuse

Current limiting protector 
open

Reset shop/house breaker, 
determine why problem 
happened

Pressure switch bad

Motor will restart when cool

Tank is full of air

Compressor will tum on 
when tank 
Pressure drops to cut- in 
pressure

Motor hums but cannot run 
or runs slowly

Low voltage

Check with voltmeter

Wrong gauge wire or length 
of extension cord

Check for proper gauge wire 
and cord length

Shorted or open motor 
winding

Take compressor to service 
center

Defective check valve or 
unloader

Take compressor to service 
center

Current limiting protector
Protector cuts out repeatedly

LOW voltage

Check with voltmeter

Lack of proper ventilation/
room temperature too high

Move compressor to well- 
ventilated area

Wrong gauge wire or length 
of extension cord

Check for proper gauge wire 
and cord length

18

Summary of Contents for RC-5010

Page 1: ...AIR COMPRESSOR 50LITER RC 5010...

Page 2: ......

Page 3: ...USER MANUAL 3 PARTS LIST 1 ON OFF switch 2 Handle 3 Safety switch 4 Power cord 5 Drain valve 6 Coupler 7 Pressure gauge 8 Pressure regulator 9 Filter 10 Motor housing 11 Sight glass 12 Oil fill hole 1...

Page 4: ...or battery operated Cordless Power tools WORK AREA SAFETY Keep work area clean and well lit Cluttered or dark areas invite accidents Don t operate power tools in explosive atmospheres such as in the p...

Page 5: ...ectric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Using a cord suitable for outdoor use will reduce the risk of electric shock If operating a power tool...

Page 6: ...on facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards POWER TOOL USE AND CARE Don t force the power tool Use the correct power tool for your...

Page 7: ...afety of power tool is maintained Follow instruction for lubricating and changing accessories Keep handles dry clean and free from oil and grease AIR COMPRESSOR USE AND CARE Do not exceed the pressure...

Page 8: ...moisture after each day s use If unit will not be used for a while it is best to leave drain valve open unit such time as it to be used This will allow moisture to completely drain out and help preve...

Page 9: ...ding Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rule will reduce the risk of serious personal...

Page 10: ...with air connected Storing the tool with air connected can result in unexpected firing and possible serious personal injury Protect your lungs Wear a face or dust mask if the operation is dusty Follo...

Page 11: ...ny parts on the packing list are already assembled to your product when you unpack it Use of a product that may have been improperly assembled could result in serious personal injury Inspect the produ...

Page 12: ...glass is located above the tank There is a red dot in the center of the glass 2 An oil level at the top of the red dot indicates oil is at maximum level 3 An oil level at or below the bottom of the r...

Page 13: ...zles and tire inflators TO MOVE THE AIR COMPRESSOR Ensure the air compressor is unplugged make sure the power cord is secured in the cord warp 1 Facing the back of the air compressor grasp the handle...

Page 14: ...ut off again when the desired pressure is reached WARNING Never exceed the air tool s pressure rating as recommended by the manufacturer When using this air compressor as an inflation device always fo...

Page 15: ...ng counterclockwise reduces air pressure at the outlet 8 Following all safety precautions in the air tool manual You may now proceed to use your air powered tool WARNING Air powered tools may require...

Page 16: ...N 1 Turn the air compressor off 2 Pull the ring on the pressure relief valve to release until pres sure gauge reads less than 1 4 bar 3 Release the ring 4 Rotate drain valves counterclockwise to open...

Page 17: ...ompressor on and allow the tanks to fill The compressor will shut off when the pressure reaches the preset maximum 2 Turn the air compressor off 3 Pull the ring on the safety valve to release air for...

Page 18: ...of air compressor maintenance it is also advised that the oil is routinely checked for proper levels WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating oils etc...

Page 19: ...ilter cover and secure it by turning it clockwise CHANGING THE OIL Replace the oil after the first 10 hours of operation and every 100 hours following the oil change The sight glass located above the...

Page 20: ...er Shop house breaker open Replace shop house blow fuse Current limiting protector open Reset shop house breaker determine why problem happened Pressure switch bad Motor will restart when cool Tank is...

Page 21: ...sture in Discharge air Excessive water in air tanks Drain tanks High humidity Move to area of less humidi ty use air line filter Compressor runs continu ously Defective pressure switch Take compressor...

Reviews: