background image

 

7

Air Nailer F30F                                              http://www.rongpeng.com 

 

6. Trouble shooting 

(See Table 1) 

SYMPTOM 

PROBLEM 

SOLUTIONS 

Air  leak  near  top  of 

tool or in trigger area   

1. O-ring in trigger valve is damaged. 

2. Trigger valve head are damage. 

3. Trigger valve stem, seal or O-ring are damaged. 

1. Check and replace O-ring. 

2. Check and replace. 

3.

Check and replace trigger valve stem, seal or O-ring

 

Air leak near bottom of 

tool. 

1. Loose screws. 

2. Worn or damaged O-rings or bumper. 

1. Tighten screws. 

2. Check and replace O-rings or bumper. 

Air leak between body 

and cylinder cap. 

1. Loose screws. 

2. Worn or damaged O-rings or seals. 

1. Tighten screw. 

2. Check and replace O-rings or bumper. 

Blade  driving  fastener 

too deep. 

1. Worn bumper. 

2. Air pressure is too high. 

1. Replace bumper. 

2. Adjust the air pressure. 

Tool  does  not  operate 

well:  can  not  drive 

fastener  or  operate 

sluggishly.   

1. Inadequate air supply. 

2. Inadequate lubrication. 

3. Worn or damaged O-rings or seals. 

4. Exhaust port in cylinder head is blocked. 

1. Verify adequate air supply. 

2. Place 2 or 6 drops of oil into air inlet. 

3. Check and replace O-rings or seal. 

4. Replace damaged internal parts. 

Tool skips fasteners. 

1. Worn bumper or damaged spring. 

2. Dirt in front plate. 

3. Dirt or damage prevents fasteners from moving 

freely in magazine. 

4.  Worn  or  dry  O-ring  on  piston  or  lack  of 

Lubrication. 

5. Cylinder covers seal leaking. 

1. Replace bumper or pusher spring. 

2. Clean drive channel on front plate. 

3. Magazine needs to be cleaned. 

4. O-ring needs to be replaced. 

    And lubricate. 

5. Replace Sealing washer. 

Tool jams. 

1. Incorrect or damaged fasteners. 

2. Damaged or worn driver guide. 

3. Magazine or nose screw loose. 

4. Magazine is dirty. 

1. Change and use correct fastener. 

2. Check and replace the driver. 

3. Tighten the magazine. 

4. Clean the magazine. 

 

 

 

 

 

 

 

 

Summary of Contents for F30F

Page 1: ...ger period of time or not adequately managed and properly maintained Wear eye protection Content 1 Technical data 2 7 Actuating systems 1 1 Fastener 3 Compressed air system 1 2 Accessories 4 Preparing...

Page 2: ...r driving tools The fastener driving tool and the fasteners specified in the operating instructions are to be considered as one unit safety system quick action couplings shall be used for connection t...

Page 3: ...number of driving operations etc Depending in the conditions at the workplace and the form of the workplace individual noise attenuation measures may need to be carried out such as placing work pieces...

Page 4: ...ese tool are marked with an inverted triangle behind the serial number and are not permitted for use without an effective safety yoke 2 7 Actuating systems Depending on their purpose fastener driving...

Page 5: ...est point in the direction to the compressor Easily accessible water separators should be installed at the lowest points Junctions for users should be joined to the pipelines from above Connecting poi...

Page 6: ...void triggering the fastener driving tool if the magazine is empty Any defective or improperly functioning fastener driving tool must immediately be disconnected from the compressed air supply and pas...

Page 7: ...not operate well can not drive fastener or operate sluggishly 1 Inadequate air supply 2 Inadequate lubrication 3 Worn or damaged O rings or seals 4 Exhaust port in cylinder head is blocked 1 Verify a...

Page 8: ...ring 21 3x3 Piston assembly O ring 30x1 8 Cylinder Bumper Rubber Washer Rectangle Washer Trigger Valve Stem Trigger Valve Pipe O ring 1 7x2 Trigger Valve Guide O ring 11 2 2 Compressed Spring Trigger...

Reviews: