background image

Version:1.0 

Creator: 5166 Validator: 5160

October 2021

4310.D

T2 Instructions

General Instructions

Removing the setting stem can only 

be effected in Pos. I.

The use of supporting screws is es-

sential when mounting the hands.

Permitted hand setting strengths:

Hr / min. hands:  <40N

Other hands: 

<30N

During  quick  date  correction  (set

-

ting stem in position II), a date swit

-

ching  speed  of  5  d/s  must  not  be 

exceeded.

Fitting dial and hands

• Crown in position III

• Wind hour hand forward, until the date changes

• Remove working hand

• Fit the dial

• Place all hands toward 12 o‘clock

• Wind hands forward to set actual time

• Crown in position II

• Set date

• Crown in position I

Setting the tide

• Keep one of the two pushers pressed for at least one second (tide hand 

jumps forward).

• 

Press one of the two pushers briefly; the hand jumps forward each time one 

30th (12min 24.4s) of the level for high or low tide.

• Press one of the two pushers for a long time; continuous correction.

• By leaving the pushers pressed for at least 10 s; the hand position is 

automatically maintained an correction mode is quitted.

Date switching duration: 

~1¼hrs

Characteristics of electronics

The  function  configurations  in  the  movement  are  identical  for  both  pusher 

positions independent from the position the pusher is positioned in the watch 

case.
After inserting the battery, the tide hands jumps the first time after 60 s and 

continues with a jump every 12 min. 24 s.
Pulling the stem causes an interruption of the tide counter in the IC. When the 

crown is pushed back, the counting continues from as from the last position. 

A reset can only be achieved when removing the battery.

Movement holder 

Setting hands

H5XXX.1A

Movement holder

Removing setting stem

H5XXX.1T

DOMVT223e

Summary of Contents for startech 4000

Page 1: ... Product Specifications Analog quartz movement Line startech Caliber 4310 D Size 12 Version Swiss Made 7 Jewels gold plated Swiss Parts 4 Jewels nickel plated Standard battery life 60 months Hand fitting height 1 Features Setting the tide cycles by pushers Date 14 04 2022 www ronda ch Page 1 ...

Page 2: ...Stem thread 0 90 mm Standard battery 395 Standard battery life 60 months Battery voltage 1 5 V Current consumption typical 1 19 μA Date Mechanism not in Gear Current consumption maximum 1 65 μA Date Mechanism not in Gear Useful torque second typical 6 μNm Useful torque minute typical 300 μNm Useful torque center stop second typical 7 μNm Operating temperature 0 50 C Instantaneous rate 10 20 sec mo...

Page 3: ...ung R 13 50 50 Pushed in Poussoirs Drücker Pushers 200 0 2 7 Ø 2 4 S 0 8 9 75 5 98 6 32 5 35 12 32 13 26 2 1 Côté fond de boîte Seite Gehäuseboden Case back side B 30 1 A 30 1 2 5 1 2 5 2 5 1 2 5 Position pour extraire la tige Position zum Entfernen der Stellwelle Position to remove the stem Pile Batterie 395 Ø 9 50 x 2 60mm Battery Dégagement cercle d entourage pour poussoir Freistellung Gehäuser...

Page 4: ... to hand fitting heights 3 0 100 0 2 x 20 Ø 0 75 0 14 0 5 max 3H Stellw Tige Stem Datum Date Date 6H 12 3 6 9 ø 10 12 92 12 92 01 No 5010 841 4310 D Sous réserve de modifications Aenderungen vorbehalten Modifications reserved Dial Cadran RONDA 16 08 2019 Modified Scale 10 1 dh5221 Issued Mod No Released YES 06 05 2021 dh5221 ÄA 43820 Page 1 1 A4 Tolerance 20 µm Zifferblatt 12 ...

Page 5: ...ouvement Arbeitstellwelle im Werk eingebaut Working stem implemented in the movement Code dunkelblau dark blue No d article Artikelnummer Part number L L1 3000 177 L2 L3 S D 20 00 10 23 24 23 10 15 1 10 0 90 Tige normale Stellwelle normal Stem normal No d article Artikelnummer Part number L4 L5 min 3000 040 L6 S1 S2 D1 12 00 1 90 2 60 0 90 1 35 0 90 Rallonge de tige Stellwelle Verl ngerung Stem ex...

Page 6: ...one of the two pushers briefly the hand jumps forward each time one 30th 12min 24 4s of the level for high or low tide Press one of the two pushers for a long time continuous correction By leaving the pushers pressed for at least 10 s the hand position is automatically maintained an correction mode is quitted Date switching duration 1 hrs Characteristics of electronics The function configurations ...

Page 7: ...o location Changing your location may require an adjustment of the Tide state After inserting the battery the first pulse for the Tide hand occurs after 60 seconds Next pulses follow at the interval of 12 minutes 24 4 seconds Adjusting the Tide state by the pusher has no effect to the interval of the motor pulses nor will the Tide function be re initialized Please note In order to set the time to ...