T2 Instructions
General Instructions
Removing the setting stem can only
be effected in Pos. I.
The use of supporting screws is es-
sential when mounting the hands.
Permitted hand setting strengths:
Hr / min. hands: <40N
Other hands:
<30N
During quick date correction (set
-
ting stem in position II), a date swit
-
ching speed of 5 d/s must not be
exceeded.
Fitting dial and hands
• Crown in position III
• Wind hour hand forward, until the date changes
• Remove working hand
• Fit the dial
• Place all hands toward 12 o‘clock
• Wind hands forward to set actual time
• Crown in position II
• Set date
• Crown in position I
Setting the tide
• Keep one of the two pushers pressed for at least one second (tide hand
jumps forward).
•
Press one of the two pushers briefly; the hand jumps forward each time one
30th (12min 24.4s) of the level for high or low tide.
• Press one of the two pushers for a long time; continuous correction.
• By leaving the pushers pressed for at least 10 s; the hand position is
automatically maintained an correction mode is quitted.
Date switching duration:
~1¼hrs
Characteristics of electronics
The function configurations in the movement are identical for both pusher
positions independent from the position the pusher is positioned in the watch
case.
After inserting the battery, the tide hands jumps the first time after 60 s and
continues with a jump every 12 min. 24 s.
Pulling the stem causes an interruption of the tide counter in the IC. When the
crown is pushed back, the counting continues from as from the last position.
A reset can only be achieved when removing the battery.
Movement holder
Setting hands
H5XXX.1A
Movement holder
Removing setting stem
H5XXX.1T