20
ENGLISH
FRANÇAIS
2001720
6. Check the oil level sight glass (
D, fig.1 & 2
). The oil should show level with
the red dot in the centre of the viewing window.
7. Find the oil fill breather cap (
E, fig.1 & 2
).
8. Gently screw the oil breather into the oil fill hole. Do not cross-thread or
over-tighten.
INITIAL BREAK-IN
1. Open (turn the brass knurled knob out, counter-clockwise) the air tank
Moisture release petcock (
fig.3
) to permit air to escape, so no air pressure
builds up in the air tank.
2. Plug power supply cord into correct power source.
3. Pull up on the Auto-On/Off switch (
C, fig.1 & 4
) to start the compressor.
4. Run the compressor in this no-load condition for 1 to 20 minutes to
lubricate the bearings and pistons.
. Close (turn the knurled knob in, clockwise) the air tank Moisture release
petcock.
6. Pressure will build in the tank and the Pressure switch will stop the pump
when it reaches the pressure set on the regulator. Your compressor is now
ready for use.
NOTE:
During the break-in period, there may be a slight smell as the electrical
motor brushes seat themselves. This may last for about 5 minutes and is
normal.
CAUTION!
If the compressor does not run properly after 15 minutes of the
break-in or if you notice any abnormalities, please contact the service
centre.
OPERATING INSTRUCTIONS
Fig. 2
Fig. 3
Fig. 4