Do not wipe the outer casing with sanitary alcohol as this might remove the paint on
the casing. Use mild detergent instead.
After using for 15-20 days, if the appliance does not spray mist or sprays little mist,
clean the transducer and Water Shortage Protection Sensor (item 8 in diagram in
Technical Specification) as in previous step.
Switch off, unplug the unit and pour out all of the water from the water cavity after
use. Dry the appliance thoroughly before storage.
Clean the appliance after long periods of storage.
15.
Troubleshooting
Problem
Probable Cause
Remedy
No mist generated or mist
intensity is weaker than before
No water of very little water in
cavity.
Switch of the humidifier. Fill the
water cavity with water and try
again.
Water cavity overflowed
Switch off the humidifier and pour
out excess water.
The upper casing is not attached
properly to the base unit.
Switch off the humidifier. Detach
the upper casing and reassemble it
with the base unit again according
to the above mentioned guideline.
The 2 or 4 hours of operation
period is complete.
Press and hold the power button
again to restart the unit.
Distilled water or cold water has
been used in the unit.
Replace with tap water or mineral
water of room temperature.
Water shortage protection sensor
and/or ultrasonic transducer not
cleaned properly and covered
with dirt.
Please clean item carefully,
following instructions above.
The power jack is not connected
firmly with control unit, or the
AC/DC adaptor is not connected
firmly with the mains.
Please re-check to ensure all
power connections are done
properly.
Water leaks out from the unit
The humidifier is shaken
accidentally and water spilled out
unexpectedly.
Switch off the unit, detach the
power cord and dry the unit
thoroughly before re-use.
Wind blows the mist back to the
humidifier and mist condenses on
the surface.
Reposition the humidifier to
accommodate the wind blow
direction.
Further copies of these instructions can be downloaded at www.rompa.com
We hope you find our instructions invaluable. If you have any suggestions for improving
them further your comments will be greatly received – please contact us at