10-3. BLACKOUT
If electric power supply failed, control system reacts as follows;
1) MANUAL BURNOUT MODE
When electric power supply is restored, the machine does not resume heating automatically.
Press START key, so that the machine will resume its running.
2) AUTOMATIC BURNOUT MODE (blackout and recovery before the set time of Step 1)
In case blackout happened during standing by and restored before the set start time of Step 1,
the machine resumes its running when power supply is restored.
In this case, finish of total burnout cycle will not be delayed. See the figure as follows.
3) AUTOMATIC BURNOUT MODE (blackout before the set time of Step 1 and recovery after the
set time of Step 1.
In case blackout happened during standing by restored after the set time of Step 1, the machine
will be activated automatically again at the time when power supply returns.
However, finish of total burnout cycle will be delayed for the time equal to blackout time period
from the set start time of Step 1 to power recovery.
See the below figure.