Installation
INSTALLATION AND WIRING INSTRUCTIONS
This thermostat can be programmed to automate your heating cycle. The programming is based upon 4
Periods per day - 7 day cycle, WAKE - LEAVE - RETURN - SLEEP / Monday - Sunday. A time and temperature
will need to be set for each period of each day. This will then allow the thermostat to change the
temperature up and down as per your set temperature for each period to suit your lifestyle.
Note: There is no On or Off settings in this mode but simply different temperatures. If you set a tempera
-
ture below ambient room temperature the thermostat will keep the heating off. If you set a temperature
above Ambient room temperature the thermostat will turn the heating on until the set temperature is
achieved. The default automated setting times and temperatures are shown in the table on page 10.
Replace front panel whilst
ensuring the pins engage
properly in the circuit board.
Fix the back section to wall box
with screws provided.
Wire the back section in as shown
in the wiring diagram on page 14.
Loosen fixing screw on the base of
the thermostat and separate front
panel from back section.
13
14
Caution: Ensure power is disconnected when wiring!
Step 1
Step 2
Step 3
Step 4
Pow
er
Load
Note: This thermostat should be mounted in a standard deep fit 1
gang back box. We recommend a 47mm deep back box.
Heating
System