Settings Pages.
Depending upon how you use your thermostat and the type of
heating system installed you may need to adjust the internal default
settings on this thermostat. To access these settings,
1: Make sure the unit is in the ON position.
2: Press OFF in bottom right hand corner.
3: Confirm off by pressing OK in centre of screen.
4: Within 2 seconds press and hold on Time / Day top left hand
corner of the screen for 5 seconds. NOTE: You need to press and
hold on VERY top of screen where Time and Day is.
Temperature Offset / Calibration.
This allows the temperature to be
calibrated should the temperature
displayed on the screen not be true
to the actual air / floor temperature.
Dead Zone. This is the number of degrees above & below the set
temperature the regulated temperature will be permitted to go
before turning the heating off or on to keep the regulated
temperature within these limits. We suggest setting this to 1.5
especially in quiet areas.
Set Point Max / Min, (Also see MENU setting ). This is the
Maximum & Minimum temperatures the thermostat can be set to.
NOTE: A yellow triangle will appear on screen if the regulated
temperature on screen ever passes these set points.