Rollerdor RD10X2 Control Box, Edition 2022/1

Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required. 

The control box is currently in hold to run operation for 
open and close, if the limits of the motor have not been 
set then please use the open and close buttons that 
can be found at the bottom right corner of the yellow 
transformer (Fig.17.1) to set these limits.’

Once installation is complete, slide back down dip 
switch ‘2’ in the control panel, this can be found on 
the four dipswitch block at the bottom middle of the 
receiver board (usually blue or red) 

(fig.6)

.

For access to the base rail unit on the right side (where 
the writing is), push at the end of the grey cover and 
slide to the left. This will give access to the board 

(fig.7)

.

Fix the wireless safety edge to the centre of the bottom 
slat of the door on the inside with the safety edge fitted 
level and square with the writing the correct way up .

Check to make sure both dip switches are down in the 
base rail unit 

(fig.8A)

, these are just off centre at the 

top of the unit (usually blue  
or red).

Set the sensitivity on the small dial 

(fig.8B)

 to 3 to 

start. This can be adjusted for optimum operation 
(smaller the number the more sensitive the unit is, and 
the dial has to be set on a whole number).

Remove the plastic tab from the batteries and the LEDs 
will blink on the safety edge unit.

Inside the receiver box press and hold the “PROG” 
button on the receiver card (this is the card plugged 
onto the board) until you hear a single beep 

(fig.9)

then within 5 seconds press and hold the “PROG” 
button on the wireless safety edge 

(fig.8C)

 and you will 

hear another beep from the receiver box. 

Wait several seconds until you hear 2 beeps from the 
receiver box and pairing is complete.

fig.6

fig.7

2. SETTING UP WIRELESS 

SAFETY EDGE KIT

       (RD10X2 VELOCITY SAFETY EDGE)

PROGRAMMING BASE RAIL UNIT

PUSH

GREY

SECTION

Summary of Contents for RD10X2

Page 1: ...Rollerdor RD10X2 Control Box Edition 2022 1 RD10X2 Control Box Installation Guide for Roller Garage Doors Edition 2022 1 ...

Page 2: ...ave a safety brake with a cable then run the two core cable from the safety brake end across to the same end as the receiver box making sure to securely fix the cable out of the way of the working mechanism 6 Remove the green 5 terminal block in the bottom left corner fig 5 and you will see letters printed on the circuit board 7 Wiring as follows Mains Power N Neutral Blue 3 core cable power L Liv...

Page 3: ...ing in the upward direction swap motor wires black to U and brown to V DIRECTION OF ROTATION fig 5 fig 4 8 Before plugging in check to make sure that there are no bare cables touching and all wires are securely fixed 9 There is a four dipswitch block at the bottom middle of the receiver board usually blue or red Slide dipswitch 2 into the up position fig 5 Pictures are for illustration purposes on...

Page 4: ...inside with the safety edge fitted level and square with the writing the correct way up 5 Check to make sure both dip switches are down in the base rail unit fig 8A these are just off centre at the top of the unit usually blue or red 6 Set the sensitivity on the small dial fig 8B to 3 to start This can be adjusted for optimum operation smaller the number the more sensitive the unit is and the dial...

Page 5: ... fig 9 fig 10 fig 8 A B C The curtain will open slightly and close again The curtain will then open and fully stop Press release the START button again fig 10 and the curtain will close pause and then reopen On final closing when the curtain is 20mm from the floor press and release START button The curtain will carry on moving but the red light above PROGRAM will flash purple red 1 2 3 4 Please be...

Page 6: ...11A until you hear 3 beeps and the red LED alongside C3 will illuminate then release the button 2 Press top button on handset fig 12A The panel will beep to confirm it has accepted Repeat for all other handsets 3 Leave for several seconds and the receiver box will beep twice to confirm end of programming 4 Press and hold the RADIO PROG button fig 11A until you hear 4 beeps and the red LED alongsid...

Page 7: ...rminals and board will stop beeping 4 Leave for several seconds and the receiver box will beep twice to confirm end of programming CLEARING MEMORY OF REMOTE CONTROL HANDSETS MR fig 14 1 Press and hold the PROG button fig 14A on the receiver card this is the card plugged onto the board until you hear a single beep 2 Insert screwdriver between the 2 terminals on the board forks below PROG button to ...

Page 8: ...ocker Switch fig 16 4 Up wire 3 Down wire 5 Common wire for the supply to the switch Fit Link wire from 5 to 2 To open rocker switch remove screws Key Switch fig 17 Right Block 13 Up wire Left Block 14 Down wire Right Block 14 Common wire for the supply to the switch Left Block 13 Right Block 14 Link wire between terminals To open key switch remove screw then turn key a quarter turn HARD WIRED ROC...

Page 9: ...tory issue 12345678 and press OK fig 18B The red LED will flash faster 3 Press the button fig 18A then enter the new master code followed by the button The LED will flash green 4 Enter the new master code again followed by the button fig 18A The LED will have a permanent green light for 2 seconds then go out This means it has been programmed If the second entry doesn t match the first the LED will...

Page 10: ...Norwich Norfolk NR5 9JD 44 0 1603 743215 sales rollerdor net www rollerdor net Company Registration Number 10676267 Registered Office Address Rollerdor Ltd Bankside 300 Peachman Way Broadland Business Park Norwich Norfolk United Kingdom NR7 0LB Edition 2022 1 ...

Reviews: