5
Rollerdor RD10X2 Control Box, Edition 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
PROGRAMMING RUN TIMERS & LIMITS
1
The curtain must be all the way down in the closed position
before starting.
2
Press and hold the white “PROG” button on the main receiver
board for 2 seconds until the red LED lights up and stays on,
this is next to the start button
(fig.10)
.
3
Press & release the “START” button (next to “PROG”
button) (fig.18.1) the receiver box will now start a setup
process.
4
Wait for several seconds and the "PROG" light will turn off.
Run timer set up is now complete.
fig.9
fig.10
fig.8
A
B
C
The curtain will open slightly and close again.
The curtain will then open and fully stop.
Press & release the "START" button again
(fig.10)
and the curtain will close, pause and then reopen.
On final closing, when the curtain is 20mm from
the floor, press and release "START" button. The
curtain will carry on moving but the red light above
"PROGRAM" will flash purple & red.
(1)
(2)
(3)
(4)
Please be aware! During set up the
motor may reach thermal cut out.
If this occurs you will need to wind
the curtain down manually to allow air
to pass over the barrel and cool.
This can take up to 45 mins.
If the curtain stops (due to thermal cut
out), or once completed the error light
is on or flashing, then you will need to
clear the memory of the base rail unit
and handsets before restarting the
whole procedure
(refer to page 7
to clear memory)
.