QUICKSTART “BASIC” GUIDELINES FOR MODEL 9000 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD “FULL OPEN”

Copyright 2018 DoorKing, Inc. All rights reserved.

9000-066-J-8-18

Use 3/4-inch conduit 

with sweeps.

3-Wire

Below ground depth of the concrete pad is 

determined by soil conditions and local building 

codes (reinfor

ced concrete recommended).

Switch 

1

in ON

position

.

Use (4) 3/

8” x 2” Sleeve Anchors 

(Not 

supplied). 

Loop 

Conduit 

AC Power 

Conduit 

Concrete

 

Pad

Opening 

Direction 

Concrete pad

MUST be level!

Chain Bracket

Chain, Conduit Area and Concrete

4” minimum

above ground

.

3.5”

4.5”

13.5” 

24”

24”

Conduit Area

Operator   Chassis

Idler

Wheel

Center

Positio

n

Botto

m

Positio

n

Idler Wheel

Top Position

Center 

of 

concrete 

pad

Concrete Pad

SW 

1

1

234567

8

ON

Opening

Direction

Switch 

1

in OFF

 

position

.

SW 

1

1







ON 

Loop Detectors

Radio Receiver

B

B

B

A

E

D

C

Not included - Refer to the Installation/Owner’s manual 

for more information about DoorKing’s Plug-In loop 

detectors. DoorKing highly recommends that loops and 

loop detectors are installed with this slide gate operator. 

DoorKing offers a free “Loop and Loop-Detectors 

Information Manual” PDF located at DoorKing’s web 

site for more information. www.doorking.com

C

Not included - Refer to a specific Radio Receiver 

Manual (available from www.doorking.com) for more 

information on radio receivers and antenna installation. 

(See reverse side for wiring)

High Voltage Connection

Tip: It is recommended that a surge suppressor be 

installed on the input high voltage power line.

GATE OPERATOR MUST BE PROPERLY GROUNDED!!

Adjust the 2 limit nuts by depressing the lock plate and spin nuts to 

desired open and closed gate positions. After adjusting, make sure 

the lock-plate is engaged in the slots on the limit-nuts to prevent 

them from rotating.
Note: Partial Open Feature is optional and not used for a fully 

opening gate, see manual for more information.

Adjust the chain nuts to tighten the chain. The chain 

should sag no more than one (1) inch per 10 feet of 

chain travel. Do not over tighten the chain.

Adjustment of Limit Switches 

Chain Adjustment

Model 9000 is intended for 

installation only on sliding 

gates used for vehicles.

Pedestrians must be supplied with 

a separate access opening.

For complete safety, installation 

and adjustment of operator 

instructions, please refer to the 

Series 9000 Installation/Owner’s 

manual.

A

E

D

Neutral

Hot

115 VAC

Chassis

Ground

Input Power Line:

White - Neutral

Black - 115 VAC Hot

Green - Chassis Ground

DANGER

HIGH VOLTAGE

DIP-Switches

SW 1

1. 

Opening Direction

 

(See Illustration)

2. OFF

3. 

ON

4. 

ON

5. OFF

6. OFF

7. OFF

8. OFF

1. OFF

2. OFF

3. 

ON

4. OFF

Auto-Close Timer

Adjust

1 to 23 sec.

SW 2

4” minimum 

space 

between the 

gate and 

operator 

chassis.

Gate 

4”

TIME

DELAY

Chain brackets MUST be 

mounted so the chain 

remains the same height 

as it is on the idler wheels!

Operator and chain 

MUST be parallel to gate!

Chain bracket MUST line 

up with chain idler wheels!

Two 115 VAC

Convenience Outlets

For access control and safety device AC power.

1 23

Typical Single Operator Settings

DO NOT

 power up and cycle the 

operator until the “DIP-Switches” 

and the “Limit Switches” have 

been adjusted. Damage could 

occur to the gate and operator.

Note: “Optional” High 

Voltage Kit black and 

white wires connect 

the same as shown. 

See High Voltage Kit 

instruction sheet for 

more information.

(See reverse side for 

more information).

120 S. Glasgow Avenue

Inglewood, California 90301

U.S.A.

Warning Signs

Permanently mount signs on BOTH sides of the 

gate area and make sure they are easily visible.

Entrapment Protection must be provided for the gate 

system where the risk of entrapment or obstruction exists.

The operator will NOT run without one or more monitored 

type B1 or B2 external entrapment protection devices in 

EACH direction of gate travel (minimum of 2 external 

devices required). See manual for more information.

UL 325 August

2018 Standard