Instruction for use and installation
RBG 80 / RBG 120/ RBG 200 / RBG 30
USE
Description of the appliance
Gas rotisseries are designed for roasting poultry, game, joints, etc. using infrared radiation
(1050°C). They are available in 4 models (8 to 30 chickens capacity) and are fitted with a
drip tray.
These appliances are for professional use and must therefore be used by qualified personnel.
They must be installed in accordance with current regulations by a qualified installer and in a
sufficiently well ventilated location.
The identification plate is located on the back of the appliance.
Dimensions and capacity
Appliance
Dimensions
Weight
Number of
Spits
Capacity
(no. Of chickens)
RBG 80
940x445x760mm
30 Kgs
2
8
RBG 120
940x445x955mm
40 Kgs
3
12
RBG 200
940x445x1250mm
72 Kg
5
20
RBG 30
1345x480x1285mm 120 Kg
5
30
Technical data
Appliance
Heat
output
Number of radiant
Burners
RBG 80
11kW
2
RBG 120
16.5kW
3
RBG 200
27.5 kw
5
RBG 30
38 kw
10
Operation
The appliances are fitted with 2 to 5 motors which each drive a spit.
Lighting :
Press the knob and turn it on the star position
Place a flame close to the pilot light or the burner
Keep the knob pressed in for about 5 seconds
The pilot light or the burner will then remain lit
Turn the knob on the big flame position
A thermocouple cuts off the gas supply if one of the radiant burners goes out.
It is recommended to turn off the burner when the spit support is empty, to avoid a high
temperature on the door.
Care and maintenance
Your appliance should be cleaned regularly using a damp sponge.
Do not clean your appliance under running water: water entering the system might damage
it.
For better and long lasting performance, regular checking carried out by qualified installer
are recommended.
Your appliance can operate on the various types of liquid petroleum gas. To change from
one gas to another requires the intervention of qualified installer.
Installation
The appliance must be installed in accordance with current regulations in a sufficiently
well ventilated location.
The fresh airflow required providing air for combustion is:
RBG 80
22m3/h
RBG 120
33m3/h
RBG 200
55 m3/h
RBG 30
76 m3/h
NB:
The side panels of your appliance must not be placed next to a wall or partition
made from combustible material; otherwise, they must be covered in an effective heat
insulating material.
A distance of 30cm from the partition is deemed sufficient.