1. Compatible Controllers

p2

2. Installation

p3

2.1 WARNING: Important Safety instructions to be read before installations

p3

2.2 Assembly

p4

2.3 Wiring Diagram

p4

3. Programming & Use

p4

3.1 Warning: Important safety instructions to be read prior to operation

p4

3.2 Overview of P2 function – How to activate setting mode

p5

3.3 Overview of operational modes

p5

3.4 Pairing motor to transmitter

p6

3.5 Setting top & bottom limits

p7

3.6 Set Favourite position

p8

3.7 Impact Detection

p9

3.8 Copy Channel from an existing primary transmitter

p9

3.9 Activate / Deactivate Fabric Tension Mode

p10

3.10 Switch between Auto & Manual Lock Mode

p10

3.11 Adjusting Tension Level

p10

4. Troubleshooting

p11

COMPATIBLE CONTROLLERS

RF500s

RF400s

A.R.T | Wind & Light Sensors

A.R.T | Motion Sensor

Page. 2 of 12

Summary of Contents for Automate FT

Page 1: ...N Impact detection senses an obstacle in the blinds path and redirects the blind to protect the motor hardware and fabric ensuring product longevity An intermediate setting allows for a customised fav...

Page 2: ...P2 function How to activate setting mode p5 3 3 Overview of operational modes p5 3 4 Pairing motor to transmitter p6 3 5 Setting top bottom limits p7 3 6 Set Favourite position p8 3 7 Impact Detection...

Page 3: ...e drive adaptor should be evenly fixed with 4 pieces of 4x10 countersunk self tapping screws Ensure screw tip does not penetrate through the internal surface of the drive Motor is to be installed in h...

Page 4: ...e it cools down Isolate power prior to unplugging connector performing maintenance or window cleaning Avoid operation if frost or ice has formed on motorized unit Power off 1 2 3 AC 1 2 3 3 0 75mm 240...

Page 5: ...ro CH Press P2 RF400s RF500s Below is an overview of how to activate the P2 function on your chosen primary controller 3 3 OVERVIEW OF OPERATIONAL MODES 3 SELECTABLE MODES TENSION Top limit Bottom lim...

Page 6: ...REQUIRED P2 P2 within 4 seconds within 4 seconds Jog Jog 1 1 Cutting power before limit setting process is complete will result in loss of pairing To reset motor P2 STOP P2 Removes all emitters delet...

Page 7: ...t Enter step mode 1 1 P2 Jog Jog Jog DOWN UP STOP STOP 1 If pairing multiple motors to a single channel ensure power is switched off prior to proceeding to the next motor Cycle blind up and down first...

Page 8: ...ion STOP STOP P2 Jog 1 SETTING FAVORITE POSITION DELETING FAVORITE POSITION g ged when the motor stop working or work on the motor head the charging time is se charging the motor battery firstly didn...

Page 9: ...CHANNEL FROM AN EXISTING PRIMARY TRANSMITTER P2 P2 ON PRIMARY TRANSMITTER 1 Jog ON NEW TRANSMITTER P2 On primary secondary multi channel remotes ensure desired channel is active first 3 7 IMPACT DETE...

Page 10: ...ETWEEN AUTO MANUAL LOCK MODE TENSION MODE ON TENSION MODE OFF Beep Beep x 1 x 2 P2 STOP DOWN AUTO LOCK MANUAL LOCK Beep x 2 x 5 P2 UP UP Fabric Tension Mode must be ON to switch between Auto Manual Lo...

Page 11: ...oltage too low 2 Errors in line connection 3 Overload 4 Installation error 5 Transmitter batteries are Flat 1 Check voltage is within the rating specified 2 Check the wiring 3 Verify motor capacity to...