background image

1

ZBX-540E   Safety Cover

Assembly Instructions

This document provides instructions for service personnel. These procedures should not be
performed by the end user.

————————— Important Notes on Assembly Operations —————————

WARNING

Before attempting these operations, unplug the power cord for the modeling ma-
chine. Failure to do so may result in danger of electrical shock, electrocution, or en-
tanglement.

WARNING

After completing the operations, be sure to verify the operation of the interlock switch,
and never use the machine if the switch does not operate correctly.

Before attempting these operations, read through this manual and familiarize yourself with the installation loca-
tion and orientation of each part.

Assembly operations are to be performed by two or more persons.

To prevent injury, wear gloves when performing these operations.

Be sure to use some means to secure the emplacement base and safety cover.

Supported model

MODELA Pro II  MDX-540

External dimensions

W x D x H: 1,042 x 1,030 x 978 mm (41 x 40.6 x 38.5 in.)

Weight

68 kg (150 lb.)

Summary of Contents for ZBX-540E

Page 1: ...perations be sure to verify the operation of the interlock switch and never use the machine if the switch does not operate correctly Before attempting these operations read through this manual and fam...

Page 2: ...eft side frame x 1 Right side frame x 1 Left side panel A x 1 Left side panel B x 1 Right side panel A x 1 Back panel A x 1 Back panel B x 1 Hatch panel x 1 Top frame A x 1 Top frame B x 1 Back frame...

Page 3: ...rs A x 2 Wiring cover B x 1 Wiring cover C x 1 Handy panel bracket x 1 Handy panel hanger x 1 Handles x 2 Rubber caps x 3 Screws M5 x 8 mm x 4 Screws silver M4 x 8 mm x 52 Screws black M4 x 8 mm x 4 S...

Page 4: ...4 Screws with flange M4 x 14 mm x 4 Tapping screws M3 x 8 mm x 2 Nuts with flange M4 mm x 2 Cable retainer x 1...

Page 5: ...modeling machine at the installation loca tion Remove the switch box from the modeling machine 4 screws Pull out the wiring from the switch box Note Place the removed switch box on the modeling machi...

Page 6: ...frames open slightly and fit the rollers onto the rails Attach the top frame B Attach the top panels A and B Hatch panel Handle Handle Screws M5 x 8 mm Screws M5 x 8 mm T op flame B T op flame A T op...

Page 7: ...along in the frame Interlock switch Wiring covers A Screws silver M4 x 8 mm Rubber cap Cable retainer Front cover Note When installing the wiring covers B and C and the switch box be especially caref...

Page 8: ...box Connect the interlock wiring to the switch box and at tach the switch box to the front cover When doing this press in any excess wiring into the switch box Front cover Cable retainer Screws black...

Page 9: ...he left side panels A and B Attach the right side panels A and B The screws are loosened Hatch panel Front cover Magnet Hole Push plate Push plate Hatch panel Screws Switch Side frame Side panel Left...

Page 10: ...rform attachment and detachment of the ven tilation duct filter while turning it clockwise When do ing this grasp the hose at a location a short distance away from its end Handy panel T apping screws...

Page 11: ...ws silver M4 x 8 mm Back panel B Back panel B Back flame B Note Perform attachment and detachment of the ven tilation duct filter while turning it clockwise When do ing this grasp the hose at a locati...

Page 12: ...loses smoothly Close the hatch panel and start the modeling machine Make sure that cutting operation is possible when the hatch panel is closed Make sure that the interlock feature is actu ated and cu...