MIDI Implementation
35
{
Remote Parameter
Address
Parameter Name
Sys.Ex.Value
Meaning of Value
03H 02H 00H
MIDI RX Ch
00H–0FH
1–16
03H 02H 01H
RS232 SW
00H–01H
OFF, ON
03H 02H 02H
RS232 BaudRate
00H–03H
9600, 19200, 38400, 115200
03H 02H 03H
GPI 1 ASSIGN
00H–11H
N/A, CH SEL 1–4, MEMLOAD 1–8, USER 1–5
03H 02H 04H
GPI 2 ASSIGN
00H–11H
N/A, CH SEL 1–4, MEMLOAD 1–8, USER 1–5
03H 02H 05H
GPI 3 ASSIGN
00H–11H
N/A, CH SEL 1–4, MEMLOAD 1–8, USER 1–5
03H 02H 06H
GPI 4 ASSIGN
00H–11H
N/A, CH SEL 1–4, MEMLOAD 1–8, USER 1–5
03H 02H 07H
GPO 1 TYPE
00H–01H
ONESHOT, ALT
03H 02H 08H
GPO 2 TYPE
00H–01H
ONESHOT, ALT
03H 02H 09H
GPO 3 TYPE
00H–01H
ONESHOT, ALT
03H 02H 0AH
GPO 4 TYPE
00H–01H
ONESHOT, ALT
{
Memory Parameter
Address
Parameter Name
Sys.Ex.Value
Meaning of Value
03H 03H 00H
MEMORY RECALL TRIGGER
00H–07H
MEMORY 1–8
03H 03H 01H
LOADED MEMORY NO
00H–07H, 7FH
0H–07H: MEMORY 1–8, 7FH = no load (Read Only)
03H 03H 02H
MEMORY SAVE TRIGGER
00H–07H
MEMORY 1–8
03H 03H 03H
MEMORY INIT TRIGGER
00H–07H
MEMORY 1–8
03H 03H 04H
MANUAL MODE
00H–01H
OFF, ON
03H 03H 05H
POWER ON LOAD
00H–08H
OFF, MEMORY 1–8