35
Controlling the AR-200R from an External Device (Control Input Connectors)
Applications
Connecting Equipment
Connectors Used in Binary Rec
1–8: Phrases are specified in binary format using
combinations of 0 (Off) and 1 (On).
9, 10: Combinations of 0 (Off) and 1 (On) are used to specify
record, erase, and playback.
15–18 (CONT OUT): Outputs signals for confirming the
presence or absence of phrases.
In addition to the connectors just described, shorting Ports 11
and 12 (Ground) enables “On.”
fig.inp-23
“Important Notes on Making Connections and Switching
Operational Specifications for
Binary Rec
Phrases are specified by combinations of signals of 0 (Off)
and 1 (On) to the Port Nos. 1 through 8 as well as Port Nos.
11 and 12, and record, playback, and erase functions are
specified with combinations of control signals of 0 (Off) and
1 (On) to Port Nos. 9 and 10.
Presence or Absence of Phrases
If there is a binary-specified phrase that has already been
recorded, a signal is output from the CONT OUT connector
(Port No. 15). If there is an empty phrase, no signal is output.
* During Binary Rec, the CONT OUT connector functions as a
connector for signals confirming the presence or absence of
phrases. Note that this differs from the normal function of
CONT OUT.
fig.inp-24
Recording
9: 0 (Off)
10: 1 (On)
→
While control signals are being input, the specified phrase
is recorded. When input of the control signal stops,
recording then ends.
fig.inp-25
* Recording does not start if there is a binary-specified phrase
that has already been recorded (the recording instruction is
disabled). When recording, either specify an empty phrase or
delete the existing phrase before recording the new one.
Additionally, in Binary Rec, since a make signal is output
from the CONT OUT connector when a specified phrase has
already been recorded, this allows confirmation using a
connected external control device.
* When headphones are being used, no Busy Out signal is
output.
* When you're using the Binary Recording Mode, recording
takes place immediately, without entering trigger recording
standby.
10
1
18
15
8
Select a Phrase
9
Rec /Play /Delete
CONT OUT
12 11
GND
Tbcd
-
250
min
max
(msec)
(the presence or absence
of phrases)
Binary Specification
Port No.1--8
Tbcd
Timing Chart (The presence or absence of phrases)
Binary Phrase Output Delay Times
:
Control Out
Timing Chart (Rec)
Trw
Tbrs
Tbrh
Tbrd
Tvrd
Tbred
Tvred
300
200
100
-
-
-
-
-
-
-
300
300
100
100
min
max
(msec)
AUDIO OUTPUT
Busy Out
Port No.10
Tvred
Trw
Tbrs
Tbrh
Tbrd
Tvrd
Tbred
Binary Specification
Port No.1--8
: Play Pulse Width
: Binary Setup Time
: Binary Hold Time
: Busy Delay Time
: Audio Delay Time
: End Busy Delay Time
: End Audio Delay Time
AR-200R_e.book 35 ページ 2010年7月1日 木曜日 午前11時24分
Summary of Contents for RSS AR-200R