56
Appendices
Although the FC-300’s EXP pedals are adjusted for optimal performance when
shipped from the factory, extended use over time and under certain usage
conditions may result in the pedals going out of adjustment. If you find the pedals
exhibiting problems, such as “a failure to completely shut off the volume when used
as volume pedals,” or “MIDI messages not being output in the range corresponding
to the set values,” you can readjust the pedals using the following procedure.
1
Hold down [UTILITY] and switch on the power.
2
When “EXP1:Set to MIN” is displayed, rock EXP PEDAL 1 all the way back (so
that the toe end of the pedal is raised). Release your foot from EXP PEDAL 1,
and then press [WRITE].
3
When “EXP1:Set to MAX” is displayed, rock EXP PEDAL 1 fully forward (so
that the heel end of the pedal is raised). Release your foot from EXP PEDAL 1,
and then press [WRITE].
4
When “EXP1:Threshold” appears in the display, set the sensitivity of the EXP
PEDAL SW 1 with VALUE [
] [
], and then press [WRITE].
5
When “EXP2:Set to MIN” is displayed, rock EXP PEDAL 2 all the way back (so
that the toe end of the pedal is raised). Release your foot from EXP PEDAL 2,
and then press [WRITE].
6
When “EXP2:Set to MAX” is displayed, rock EXP PEDAL 2 fully forward (so
that the heel end of the pedal is raised). Release your foot from EXP PEDAL 2,
and then press [WRITE].
7
When “EXP2:Threshold” appears in the display, set the sensitivity of the EXP
PEDAL SW 2 with VALUE [
] [
], and then press [WRITE].
8
When the message “Complete!” appears in the display, switch off the power.
Adjusting the Expression Pedal
When you operate the
expression pedal, please be
careful not to get your fingers
pinched between the movable
part and the panel. In
households with small
children, an adult should
provide supervision until the
child is capable of following all
the rules essential for the safe
operation of the unit.
EXP1:Threshold and
EXP2:Threshold can be set to
any value from 1 through 16.
The expression pedal switch
can be switched on and off
with less pressure as the value
is lowered.
FC-300_e1.book 56 ページ 2007年4月24日 火曜日 午前10時10分