Page 12
• This mode can be selected with the remote controller
.
• In auto mode, the machine selects cooling, hea
�
ng, or
fan-only mode on the basis of T ( T =T1-Ts).
T
Running mode
T>2
Cooling
-3
T 2
Fan-only
T<-3
Hea
�
ng*
Hea
�
ng*: In auto mode, cooling only models run the fan
• AC will run in auto mode in the below cases:
• Pressing the forced auto bu
�
on.
• If AC is o
ff
, it will run in auto mode when the
�
mer
on func
�
on is ac
�
ve.
• A
�
er se
�
ng the mode, AC will run in auto mode if
the compressor keeps not running for certain
�
me.
1.8
Drying mode
• The compressor is cycled running with 10 minutes
on and then 5 minutes o
ff
. The indoor fan will keep
running at low speed.
• In drying mode, if room temperature is lower than
10
°C
, the compressor will stop and not resume un
�l
room temperature exceeds 13
°C
.
• The evaporator an
�
-freezing protec
�
on is the same as
that in cooling mode.
1.9
Forced opera
�
on func
�
on
• Forced cooling mode:
The compressor and outdoor fan con
�
nue to run and
the indoor fan runs at low speed. A
�
er running for 30
minutes, the AC will switch to auto mode with a preset
temperature of 24°C.
• Forced auto mode:
Forced auto mode operates the same as normal auto mode
with a preset temperature of 24°C.
• The unit exits forced opera
�
on when it receives the
following signals:
• Switch on
• Switch o
ff
• Timer on
• Timer o
ff
• Changes in:
• mode
• fan speed
• sleeping mode
1.10 Auto-Restart func
�
on
• The indoor unit has an auto-restart module that
allows the unit to restart automa
�
cally. The module
automa
�
cally stores the current se
�
ngs (not including
the swing se
�
ng) and, in the case of a sudden power
failure, will restore those se
�
ng automa
�
cally within 3
minutes a
�
er power returns.
• If the unit was in forced cooling mode, it will run in
this mode for 30 minutes and turn to auto mode with
temperature set to 24°C.
• If there is a power failure while the unit is running, the
compressor starts 3 minutes a
�
er the unit restarts. If
the unit was already o
ff
before the power failure, the
compressor starts 20 seconds a
�
er the unit restarts.
1.11 Refrigerant Leakage Detec
�
on
• With this new technology, the display area will show
“EC” when the outdoor unit detects refrigerant
leakage.
• When compressor is ac
�
ve, the value of the Coil
temperature of evaporator T2 has no change or very
little change.
1.12 8
°C
Hea
�
ng(Op
�
onal)
• In hea
�
ng mode, the temperature can be set to as low
as 8°C, preven
�
ng the indoor area from freezing if
unoccupied during severe cold weather.
• When the compressor is o
ff
, the indoor fan motor is
off.
1.13 Self clean(Op
�
onal)
• If you press “Self Clean” when the unit is in cooling or
drying mode:
• For cooling models, the indoor unit will run in low
fan mode for a certain
�
me, then ceases opera
�
on.
• For heat pump models, the indoor unit will run in
fan-only mode, then low heat, and
fi
nally in fan-
only mode.
• Self Clean keeps the indoor unit dry and prevents
mold growth.
1.14 Follow me(Op
�
onal)
• If you press “Follow Me” on the remote, the indoor
unit will beep. This indicates the follow me func
�
on is
ac
�
ve.
• Once ac
�
ve, the remote control will send a signal
every 3 minutes, with no beeps. The unit automa
�
cally
sets the temperature according to the measurements
from the remote control.
P
ro
du
c
t
F
e
a
tu
re
s