background image

 

10

 

About Placement

 

The S-4000-SP can be used as a desktop unit or it can be rack mounted.

In addition, the rack-mount brackets can be attached at different points, allowing the 
unit to be recessed toward the rear of the rack.

 

* You can slide the S-4000-UP’s rack-mount brackets forward and attach them at the front of 

the rack, allowing you to shift the unit back, with the front panel recessed.
Installing the unit in this manner allows you to prevent plugs from protruding from the front 
of the rack when you have plugs connected.

 

Use the following procedure to remove and reinstall the S-4000-UP’s rack-mount 
brackets for recessed rack-mounting.

 

1

 

Turn off the power on all equipment and disconnect all cables from the S-

4000-SP unit.

 

2

 

Remove only the screws shown in the following diagram (6 screws on each 

side, 12 screws total), and detach the rack-mount brackets from the sides of 

the unit as shown.

 

3

 

Using the screws you removed in Step 2, reinstall the rack-mount brackets as 

shown.

 

Removing the Rack-Mount Brackets

Do not attach the rack-mount 
brackets further forward than 
the attachment holes shown in 
the figure. This will make the 
installation unstable.

S-4000-SP_e.book 10 ページ 2006年8月24日 木曜日 午前10時33分

Summary of Contents for digital snake S-4000-SP

Page 1: ...wer to each of the two internal splitters enabling uninterrupted use in the event the power happens to cut out in one of the power supplies or if there is some other sort of power interruption 201b Be...

Page 2: ...nto your outlet consult an electrician for replacement of the obsolete outlet WARNING IMPORTANT As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured mar...

Page 3: ...d from the outlet and request servicing by your dealer the nearest Roland Service Center or an authorized Roland distributor as listed on the Information page when The power supply cord or the plug ha...

Page 4: ...it 103a At regular intervals you should unplug the power plug and clean it by using a dry cloth to wipe all dust and other accumulations away from its prongs Also disconnect the power plug from the po...

Page 5: ...rom happening If you do so please make sure that the unit will not slip or move accidentally Maintenance 401a For everyday cleaning wipe the unit with a soft dry cloth or one that has been slightly da...

Page 6: ...the Rack Mount Brackets 10 Using the REAC Connector Covers 11 Attaching the Rubber Feet 11 Notes to Observe in Using the S 4000 System 12 Use and Handling of REAC Systems 12 About REAC Cables 12 Notes...

Page 7: ...way as those for the MAIN REAC ports 1 5 POWER Indicators A B These indicate the status of the power supply The corresponding indicator lights blue when power is supplied from AC INPUT A or B on the...

Page 8: ...REAC BACKUP enabling continuous use even when circumstances result in an interruption of power in one of the systems 921 To prevent malfunction and or damage to speakers or other devices always turn...

Page 9: ...e ordinary power supply is available Connect AC INPUT A to an ordinary power outlet Connect AC INPUT B to the external backup power supply Use the following procedure to secure the power plugs 1 Inser...

Page 10: ...the rack when you have plugs connected Use the following procedure to remove and reinstall the S 4000 UP s rack mount brackets for recessed rack mounting 1 Turn off the power on all equipment and disc...

Page 11: ...apers or magazines and place them under the four corners or at both ends to prevent damage to the buttons and controls Also you should try to orient the unit so no buttons or controls get damaged 929...

Page 12: ...used for REAC connections conform to the Cat5e Ethernet Category 5 standard No single cable should be longer than 100 meters Do not use cables with cut or torn coverings Do not subject cables to undue...

Page 13: ...le then the system will not automatically switch to the BACKUP REAC system cables and Reestablishing Transmission Carry out the following steps in the event a transmission failure to the split device...

Page 14: ...mic line sources from stage 8 outputs from console Cat5e cable in a redundant system for each Cat5e line in diagram Cat5e cables S 4000S 32x8 Master REAC device 32 mic line sources from the stage 8 ou...

Page 15: ...AC 230 V AC 240 V 50 60 Hz Power Consumption 13 W Dimensions 482 0 W x 224 8 D x 43 8 H mm 19 W x 8 7 8 D x 1 3 4 H inches Weight 2 8 kg 6 lbs 3 oz Operation Temperature 0 to 40 degrees centigrade 32...

Page 16: ...U S 425 Sequoia Drive Suite 114 Bellingham WA 98226 360 594 4282 Information When you need repair service call your nearest Roland Service Center or authorized Roland distributor in your country as s...

Reviews: