              user manual

 

 

6

 

 

 

FIRE LED 

 

 

CONDITION

 

EXPLANATION 

 

ON 

fire alarm

 or 

fire emergency

 is 

in progress or has recently 
occurred 

 

OFF 

All 

fire zones

 are 

operating 

normally

 

When lit, the FIRE LED 
indicates that the 
system is experiencing 
a fire alarm. When 
flashing, a problem has 
been detected on the 
fire circuit, and must be 
serviced. 

 

FLASHING 

problem has been detected

 on 

the fire circuit and must be 
serviced. 

 

 

 

BYPASS LED 

 

 

CONDITION

 

EXPLANATION 

 

ON 

At least one intrusion zone is 
bypassed, or when 

STAY

 

mode is 

selected 

The BYPASS LED is 
normally lit when 

STAY

 

mode is selected 

 

OFF 

All 

zones

 are 

operating normally 

and the system is in 

ARM

 mode

.

 

 

 

 

TAMPER LED 

 

 

CONDITION

 

EXPLANATION 

 

ON 

A zone, keypad, or an external 
module used by the system has 
been physically disturbed or 
tampered with. If disarmed without 
fixing the problem, will silent the 
sound only. 

The TAMPER LED 
indicates that a zone, a 
keypad or an external 
module has been 
tampered with, and 
requires resetting. In 
some cases a technician 
code is required to 
restore. 

 

OFF 

All 

zones

 are 

operating normally

 

 

                    

 ZONE LED 

( LED keypad only

)

 

EXPLANATION 

 

 

CONDITION

 

SYSTEM DISARMED 

SYSTEM ARMED 

 

OFF 

The corresponding zone is 

secured 

 

FLASHING 

The indicated 

zone is 

not secured 

N/A 

The ZONE LEDs 
indicate the status of 
each of the system’s 
intrusion zones. 

FOR LCD KEYPAD the 
display indicates the 
zone's number and 
label.

 

 

ON 

N/A An 

alarm has 

occurred

 on the 

indicated zone 

 

Summary of Contents for ORBIT-PRO RP-296

Page 1: ...icators and by the sounds it makes Your ORBIT PRO security system also consists of a variety of sensors detectors and contacts placed throughout the premises and designed to recognize abnormal conditi...

Page 2: ...uthorities Chimes The chime is a series of short keypad tones which can be set up to annunciate during the disarmed period the violation of selected intrusion zone s The chime tone can be used to annu...

Page 3: ...t up by your alarm company the ORBIT PRO allows you the convenience of arming your system with the front door open After which you must close the door as you leave the premises With such a door open a...

Page 4: ...page Some indicators have additional functions explained later on POWER LED CONDITION see note at left EXPLANATION ON The system is operating properly from commercial AC power its backup battery is i...

Page 5: ...d Indicates alarm condition and occurs after disarming alarmed system during the display in alarm memory mode To restore the display to normal press READY LED CONDITION EXPLANATION ON All intrusion zo...

Page 6: ...ally and the system is in ARM mode TAMPER LED CONDITION EXPLANATION ON A zone keypad or an external module used by the system has been physically disturbed or tampered with If disarmed without fixing...

Page 7: ...tion NORMAL OPERATION Activates AWAY mode and Quick Arming USER FUNCTIONS Used to change data NORMAL OPERATION Activates the STAY mode and Quick Arming USER FUNCTIONS Used to change data NORMAL OPERAT...

Page 8: ...ion that results during these emergency alarms along with other system sounds is covered in Section 4 If your system has been programmed to do so it will communicate any or all of these alarms to the...

Page 9: ...Level Those with a higher authority have access to a greater number of system functions while those with a lower authority are more restricted in what they may do There are six different Authority Lev...

Page 10: ...digit User Index number 00 to 98 Note the index number 00 belongs to the Grand Master Example For User Code 6 press For User Code 12 press 4 Carefully enter the new code and press ENTER If successful...

Page 11: ...Codes 5 2 Enter the current Master Code and press ENTER 3 To delete any other User Code enter the User Code s index number you wish to delete 2 digit for example for User Code 6 press 4 Press 0 follo...

Page 12: ...counts down the Exit Delay period and the ARM LED flashes for the above duration and than light steadily If LCD KP is in use its display will indicate the remaining Exit Delay time at the end of this...

Page 13: ...s scroll Up and Down with arrow keys to view all Not ready zones 2 To bypass such a zone s and cause it to be ignored by the system Enter your code and press Bypass LED will be lit Note If you make a...

Page 14: ...LCD Keypad proceed with the following STEP DESCRIPTION 1 Enter your User Code and press Note the keypad will display Not ready zones that belong to this user code only 2 Scroll the list Up and Down w...

Page 15: ...s If an alarm occurred the ARM LED and the corresponding zone LED will flash for Alarm memory period of about 60 sec If using LCD keypad scroll through the list of alarmed zones To exit alarm memory b...

Page 16: ...2 3 4 your duress code is 1 2 3 5 If your user code is 5 6 7 8 your duress code is 5 6 7 9 If user code is 6 7 8 9 duress code is 6 7 8 0 Under no circumstances must the Duress Code be used haphazardl...

Page 17: ...families and is therefore shared between them A common zone is armed only if all partitions sharing the zone are armed The common zone s is disarmed if any of the partitions which the zone s is assign...

Page 18: ...ith the or the keys to the desired partition or enter the partition s number The first item in the list will be ALL partition number 0 3 Press to confirm and confirmation message will be displayed for...

Page 19: ...n Slowly repeating tones until the exit delay period expires see Note 3 MAYBE see Note 1 Entering data into the User Functions mode see page 20 A one second tone if completed correctly three rapid err...

Page 20: ...r control of previously designated external devices e g an appliance a motor driven garage door etc 2 1 user code ENTER Output number ENTER in some cases only a code followed by ENTER required to acti...

Page 21: ...f the five most recent alarm conditions stored by the system 3 Not Ready Status Allows the viewing of all not ready zones 4 Zone Status Allows the display of all system zones and their current status...

Page 22: ...within the next 24 hours NEXT ARM works for one time only since the system deletes the setting after it is acted upon 4 Next Disarm Use to automatically DISARM an armed system at a specific time withi...

Page 23: ...efined during installation of the systems are not ready to ARM after Alarm or tamper condition To restore a technician code or an Anti code must be entered Entering at this location the code supplied...

Page 24: ...ding to the trouble s Refer to the following table to identify the trouble TROUBLE DESCRIPTION LCD KP LED KP RESPONSE Low Battery the capacity of the battery is low or missing and needs to be recharge...

Page 25: ...isplayed LCD keypad only it will automatically be removed from the system Phone Line Failure the telephone line used for Central Station communication is either disconnected or inoperative ZONE 6 LED...

Page 26: ...ll Trouble in Power Supply Module relates to optional Power Supply Module s NOTE reporting that the external sounder s connected to the first Power Supply Module PS 1 is not operating ZONE 11 LED WILL...

Page 27: ...able to correct it yourself otherwise your dealer or other related services may have to get involved Once all outstanding trouble s are corrected the rapidly flashing POWER LED on your keypad s will...

Page 28: ......

Page 29: ...6 Silencing an Alarm USER CODE ENTER Page 15 Bypassing a Zone USER CODE BYP ZONE NUMBER TO BE BYPASSED ENTER Page 13 20 Utility Output Operation 2 1 USER CODE ENTER UTILITY OUTPUT NUMBER ENTER Page 20...

Page 30: ......

Page 31: ...ront Door Open 3 Follow me 3 Scheduling 3 Partitions 3 System Expansion 3 SECTION 2 YOUR KEYPAD 4 VISUAL INDICATORS 4 KEYS 7 SECTION 3 OPERATING YOUR SYSTEM 8 EMERGENCY KEYS 8 Police Emergency 8 Fire...

Page 32: ...manual b SECTION 4 PARTITIONED SYSTEMS 17 INTRODUCTION 17 ARMING MULTIPLE PARTITIONS 17 DISARMING MULTIPLE PARTITIONS 18 SECTION 5 SYSTEM SOUNDS 19 SECTION 6 USER FUNCTIONS 20 SECTION 7 SYSTEM TROUBLE...

Page 33: ...he problem is resolved 5 Connection to telephone company provided coin service is prohibited Connection to party line service is subject to state tariffs 6 If trouble is experienced with the ORBIT PRO...

Page 34: ......

Page 35: ...routes free from obstruction 3 Practice escape procedures and set a meeting place outdoors for a headcount of the building s occupants 4 In a home sleep with the bedroom door closed to increase your...

Page 36: ...Notes...

Page 37: ...ght 1999 Rokonet Electronics Ltd 14 Hachoma Street Rishon Letzion 75655 Israel All rights reserved No part of this document may be reproduced in any form without prior written permission from the publ...

Reviews: