7.9 Fuel system
Wing tanks volume 2 x 65 ltr.
Each tank is equipped with a vent outlet and screen filter.
Drain valve located in the lowest point of the each tank and on the
bottom edge of the firewall, on the gascolator.
Main fuel selector valve is on the central console in the cockpit.
The electric fuel pump is located on firewall.
CAUTION
Do not overfill the tanks to avoid fuel overflow through venting
tubes.
7.10 Electrical system
7.10.1 Battery
The battery is mounted on the forward side of the firewall.
7.10.2 Master switch
Master switch connects the electrical system to the 12 Volt battery and
charger/coils, controlled by the regulator. See Engine Manual for
electrical system details.
NOTE
Ignition system is independent on the power source and will
operate even with Master switch and/or breaker off.
7.10.3 Ignition Switch
Ignition must be on BOTH to operate the engine: For safety, remove
key when engine is not running.
NOTE
All switches and or engine controls are "up" or "push forward" for
operation, except the choke, cabin heat and carburetor pre-heat,
which is "Pull" for "on". Optional equipment, switches and/or fuses
are subject to change or installed as requested. See Aircraft
Equipment List and Photo and Description of equipment and controls
in the cockpit.