6
www.rojaflex.com
1.
Slide on the rear cover from the side.
2.
Remove the control unit from the housing.
Functional Description:
P2 key
=
Programming
Trimmer
=
Set sensitivity
0 = Programming mode
1 = high sensitivity
9 = low sensitivity*
1
=
Batteries (2 x AAA)
Pay attention to correct pola
rity!
2
=
Beeper
ATTENTION!
The magnet must be in the specified position
when the sensor is assembled!
The sensor beeps when the housing is closed to
signal activation.
3
=
Magnet for Readkontakt
* for folding arm awnings we recommend a
setting of max. level 3.
Please observe the instructions for the aw
ning observe!
NOTICE:
If the battery voltage drops below 2.2 V, the sen-
sor beeps at intervals of approx. 5 seconds.
Risk of fire or explosion if the battery is repla-
ced by an incorrect type!
ABS
3
The
RVS-01
is a battery-powered vibration sensor for motorized awnings.
Incoming wind generates vibrations at the drop profile of the awning.
The sensor can be set to 9 sensitivity levels and sends a retract command to the previously taught-in
receiver when the preset sensitivity level is reached (see technical data for compatible receivers).