5
●
●
●
●
Every partition can set different time for auto arm/disarm.
According to the built-in clock, the system can be set up auto arm time
and auto disarm time so that one or more partitions automatically arm
and disarm in the same time every day. Each partition can be set an
independent time.
Zones Supervision
Code and Grading
Recorder, Communicator and Follow-me Number
Auto Arm/Disarm
The detector will send a report to the iDo218 to confirm itself every
2.5 hours. The iDo218 will alarm to the central monitor station if no
report received in 16 hours.
iDo218 can be set up 10 grading codes. Including a master code, an
administrator code, and six user's codes, an only arm code and one-off
disarm code. All the code can automatically generate a duress code.
Master code has the top grade. The administrator code can be used to
determine the permissions to each user.
IDo218 has build-in recorder with 20 seconds.
IDo218 has build-in digital communicator with Contact ID
communication format. It can be set up to 4 central monitor station
numbers. When alarm, iDo218 will report alarm information to the
central monitor station through telephone (PSTN/DTFM). It also can
be set up to 4 follow-me numbers. It can send pre-recorded voice to
each follow-me number when alarm.
iDo218 can be programmed to one or several partitions which can auto
arm/disarm at the same time everyday according to the build-in clock.