Roiscok iDo218 Manual Download Page 18

0

4

The

iDo218

can

save

127

events.

1

2

3

5

When

checking,

the

iDo218

will

display

the

status

o

f

D

C,

phone

line,

battery

and

siren.

Use

to

turn

on

or

of

f

some

functions

0

Set

the

buzzer

On

or

Of

f

w

hen

operating

by

keys.

Exchange

by

[ARM]

o

r

[ST

A

Y

].

User

can

check

each

detector's

T

ype,

E

ntry/

Exit

Delay

T

ime,

Partition,

Auto-arm

T

imeetc.,

u

se

ARM,

ST

A

Y

to

shift

between

detectors,

u

se

[→]

or

[←]

to

shift

b

etween

the

detector's

attributes.

Check

each

door

chime's

corresponded

d

etector

and

the

door

chime's

status.

Use

[→]

and/or

[←]

to

shift

b

etween

the

door

chimes.

4

5

6

Partition

0

is

armed

simultaneously

when

arm

any

other

partition(s).

7

8

Check

Event

T

rouble

Detector

Door

Chime

On/Of

f

Setting

Buzzer

Partition

0

N

o.

Partition

1

N

o.

Partition

2

N

o.

Partition

3

N

o.

Partition

4

N

o.

On

0000

0000

0000

0000

0000

Hot

K

ey

Item

Default

Instruction

15

i

Wireless Alarm System

Do218

Summary of Contents for iDo218

Page 1: ...iDo218 Wireless Alarm System ...

Page 2: ...nts and Technology Data of iDo218 Technical Data 6 Professional Terms CHAPTER 2 KEY PROGRAMMING Keys Functions Programming iDo218 11 Form 1 Summary of Menu 12 CHAPTER 3 SYSTEM OPERATIONS AND USAGE 19 Restore Default 19 Stay Arm 21 System Disarm 21 Arm Disarm by Remote Controller 22 1 1 i Wireless Alarm System Do218 ...

Page 3: ...rade 27 Emergency Keys 29 Door Chime 29 Entry Exit Delay 29 Events Log Wrong Code Operation Setting for against electromagnetic interference Installation and Connection CHAPTER 4 APPENDIX 35 iDo218UD and Remote PC Management 35 iDo218 Events Mounting Detectors FAQ 46 30 30 30 32 43 44 1 2 i Wireless Alarm System Do218 ...

Page 4: ...1 i Wireless Alarm System Do218 ...

Page 5: ...t is easy and delightful to installers for its menu operation The radio frequency is 433 92MHz CHAPTER 1 SUMMARY b Signal LED e Move left key h Arm LED k Arm key c Stay arm LED f In and out menu key i Trouble LED l Move right key a Power LED d Stay arm key g Confirm key j Record LED m Buzzer and record window Keys and LEDs Fig 1 2 a b c d e f g h i j k l m i Wireless Alarm System Do218 ...

Page 6: ...tion format Alarm report can be sent to 4 follow me phone numbers or and 4 central monitor station numbers at the same time It can report 4 different Central Monitor Stations With grade code and duress code Main Code Manage Code User Code One off code and only disarm code Up to 127 events log which can be checked on LCD All the events can be chosen and sent to central monitor station but cannot be...

Page 7: ...218 can be remote managed and programmed by computer With a Ni MH rechargeable battery pack the system can work more around 36 hours after lose AC supply 4 Zones and Partitions iDo218 has 62 zones can be matched with 62 different types of wireless detectors All zones can be divided into four separate partitions and a special partition Each individual partition can be individually armed and disarme...

Page 8: ... an administrator code and six user s codes an only arm code and one off disarm code All the code can automatically generate a duress code Master code has the top grade The administrator code can be used to determine the permissions to each user IDo218 has build in recorder with 20 seconds IDo218 has build in digital communicator with Contact ID communication format It can be set up to 4 central m...

Page 9: ...following three ways keys remote controller line phone or and mobile phone iDo218 can save up to 127 events including arm disarm alarm etc Professional Terms Zone Types There are 9 zone types as alarm transfer close Stay 24 hours gas medical panic and fire The transfer zone is used only for the radio repeater Alarm zone could be set as entry exit delay zone and instant zone When trigger delay zone...

Page 10: ... system called event including disarm arm alarm iDo218 power low detector power low detector communication failure clock failure siren failure and so on ARM means start the warning status for part or all of the zones DISARM means close the warning for part or all the zones During arming iDo218 will alarm when any detector is triggered During disarming iDo218 will not alarm when any detector is tri...

Page 11: ...Do218 could send the telecom number by UO correlative output port these telecom numbers could startup other equipment or function of iDo218 we called as UO correlative For example alarm correlative arm correlative system failure correlative and so on iDo218 can designate two groups of correlative detectors Each group has two detectors The iDo218 would alarm just when the two detectors are both tri...

Page 12: ...eater 2 Setting Code 3 Set Phone Partition Number 4 Check 5 On Off Setting 6 Other setting Keys Functions ARM Use for arm the system Change data or and turn to another submenu when programming such as On Off and choice partition Use for stay arm the system turn to another submenu when programming When system arming it is used for confirmation input code and then STAY Confirmation key i Wireless Al...

Page 13: ... return back to last menu or exit the programming Under programming 1 Move the cursor right 2 To next menu 3 To next line in HELP menu Under programming 1 Move the cursor right 2 To last menu 3 To last line in HELP menu Use for input the code programming and other operation for numbers Enter return back key key Key Number key 10 i Wireless Alarm System Do218 ...

Page 14: ... Press Enter Into Programming When programming the screen displays Through the board at this time with the keys on the keyboard to program operation all operations menu is as follows 11 03 12 ROISCOK iDo218Alarm System Programming iDo218 When power on the LCD screen displays as following i Wireless Alarm System Do218 ...

Page 15: ...m means 01 and 02 zones correlative by sequence The iDo218 will alarm when zone 01 triggered before 02 or decide correlative zones if have sequence use ARM key to exchange Correlative Zone 0 0 1 Help Auto Arm Press to next line press to last line Hot Key Item Default Instruction Setting for Zones partitions and repeaters Partition can be set time for arm disarm by automation according to the form ...

Page 16: ...al panic and fire And the transfer is used for radio repeater 6 In this mode let the wireless detectors and or repeater send a signal to the iDo218 After received the matching codes all the wireless detectors and or repeater will be matched in from 01 to 62 Exchange a or b by or a Detector matching b Repeater matching 2 7 Cancel all the matched detectors To be On the safe side the system will ask ...

Page 17: ...be set up 4 CMS Numbers Center Monitor Station use ARM STAY to shift from one number to another Dialing Follow me Number Times Up to 9 times Dialing CMS numbers Times Up to 9 times Hot Key Item Default Instruction 0 1 2 1234 The code is made up of 4 6 digits The code is made up of 4 6 digits The code is made up of 4 6 digits User Code 3 User Code 4 User Code 5 User Code 6 Code for Arm Only One Off...

Page 18: ...eetc use ARM STAY to shift between detectors use or to shift between the detector s attributes Check each door chime s corresponded detector and the door chime s status Use and or to shift between the door chimes 4 5 6 Partition 0 is armed simultaneously when arm any other partition s 7 8 Check Event Trouble Detector Door Chime On Off Setting Buzzer Partition 0 No Partition 1 No Partition 2 No Par...

Page 19: ...oor Detector Off Hot Key Item Default Instruction Power trouble 3 On On When the system checked there is a DC trouble it will alarm to CMS Off When the system checked there is a trouble it would not alarm to CMS Supervision 4 Off On iDo218 will report to the CMS after no signal from a detector in 16 hours Off No any report to CMS 5 Siren trouble Siren alert On On On When siren trouble the iDo218 w...

Page 20: ...mote management by PC Off Prevent remote management by PC Set the system recognized the value of environmental electromagnetic interference Set the system date and time Format MM month DD date YY year HH hour MM minute The ringing time can be from 00 90 seconds User can record voice through the microphone in the iDo218 20 seconds Use for match or and cancel detectors exchange a or b by a Controlle...

Page 21: ...es more than limit the iDo218 will report to the CMS Off No report to the CMS 9 Time test setup Siren delay Time Wrong Code Limit Keypad lock time Wrong code arm UO setup 4 minutes 3 times 10 minutes On No use pulse There are 4 types of response events can be chosen by ARM or STAY Arm alarm trouble and unused When press there are 2 types UO can be exchange by ARM or STAY pulse or lock 18 i Wireles...

Page 22: ...g AC power and standby battery Step 2 Short on the DEFAULT jumper Fig 9 and then repower the iDo218 then off the DEFAULT jumper The LCD will display as following 03 12 ROISCOK iDo218Alarm System Keypad Arm There are two keys ARM and STAY to arm iDo218 Quick Arm Press ARM to arm the system and press STAY to stay arm the system i Wireless Alarm System Do218 ...

Page 23: ... Arm All Arm Partition 1 Arm Partition 2 When arm partition 1 the LCD will display ArmP1 Arm Partition 3 or and Arm Partition 4 And then confirm by When arm all all partitions zones are armed The ArmAll will display on the LCD Repeat above operations to arm other partitions The LCD will display as ArmP1P2 or ArmP1P2P3 etc When arm a partition the partition 0 will be armed simultaneously Code Arm W...

Page 24: ...and to choose Stay All Stay Partition 1 Stay Partition 2 Stay Partition 3 or and Stay Partition 4 And then confirm by Repeat and stay arm the partitions one by one When the system is armed it will give to beeps beep beep which means the exit delay time starts make sure the windows are closed and leave the protected areas before the delay time is finished 1 When the system is armed press any key th...

Page 25: ...isarm d Matching e Unlock Key Fig 3 Remote Controller iDo104 Press arm key to arm the system press disarm key to disarm the system Remote controller can only arm disarm the whole system cannot arm disarm any single partition The keys will be auto locked in 10 seconds press Unlock Key to unlock other keys a b c d e i Wireless Alarm System Do218 ...

Page 26: ...ss to arm disarm When the system is armed disarmed successfully it will give another two sounds to confirm Hang up to finish the operation Arm disarm code 00 is used for arm all 01 is used for arm partition 1 02 is used for arm partition 2 03 is used for arm partition 3 04 is used for arm partition 4 Arm Disarm By Phone Remote Controller iDo114 Fig 4 a b c d a b c Emergency d Unlock Key Arm Matchi...

Page 27: ... disarm key 2 Enter into the panel s main menu 6 other setting choose 3a Controller match Press the matching key Fig 2 d on the remote controller until the screen display remote controller matched 10 is used for disarm all 11 is used for disarm partition 1 12 is used for disarm partition 2 13 is used for disarm partition 3 14 is used for disarm partition 4 If user operated wrongly the system will ...

Page 28: ... For iDo304CMW and iDo301W set S4 is On for iDo105 set S3 is On 1 Press key entering into the control panel to programming status choose 1 Probe Transfer 6 Matching to write code a Prober matching input code and press to confirm The screen displays as 15 49 1 Probe Transfer 6 Matching start Matching Detector i Wireless Alarm System Do218 ...

Page 29: ...o send a signal to the control panel iDo218 the LED of the detector and iDo218 would be blink The screen will display Battery clip LED Jumper S3 iDo304CMW Fig 6 iDo304CMW Tamper switch Jumper Battery clip Sensor LED S1S2S4S5 ON OFF i Wireless Alarm System Do218 ...

Page 30: ...gas medical panic and fire And the transfer is used for radio repeater Some types are 24 hours in arming status no matter the system is armed or not As long as triggered the system will alarm at once including the following five types Panic Fire 24hrs Gas and Medical User Code and Rights Grade Note 1 After matching set detector and control panel to normal working status 2 The detector 01 means the...

Page 31: ...sarm the system just comply with the intruder s wishes to disarm the system but use Duress Code so system can send a silent duress alarm to the Central Monitor Station simultaneously All codes used for disarming are called disarm code The disarm code added 1 to the last digit would become Duress Code Duress Code and the disarm code share the first 3 digits For example User code 1 2 3 4 duress code...

Page 32: ...Door Chime Any zone has door chime function If set the chime function On and under disarm status the iDo218 will produce three short beep sound as soon as the zone is triggered For home user when door or window is opened the sound can remind the mother to take care of the kids this function needs to preset the Door Chime function as on for commercial use when the front door is opened the sound can...

Page 33: ...he limitation Wrong Code Operation Setting for against electromagnetic interference iDo218 log 127 alarm events Each event will have an auto number from 001 002 to 127 All the events will be displayed chronologically the latest event number will be 001 User can check the alarm time alarm zone and other information by keys including detector s tamper supervision trouble etc When the events are more...

Page 34: ...e central monitor alarm Alarm events is communication failure ROISCOK iDo218Anti theft system 04 07 ArmAll ArmAlcPlan 3 T a Arm all the system b There is external interference c Means calling to the CMS and follow me numbers d Means system time e Means the calling status a b c d e 15 49 5 On Off Setting 9 Noise Adjust OK 0d An inevitable feature of wireless products is susceptible to interference ...

Page 35: ... good GND post for the iDo218 Power by external adapter input 100 240VAC 50 60Hz output 12VDC 2 0A Fig 8 Installation Bracket and Holes a Installation bracket b Installation pothook c Screw holes d Installation holes e Open the housing here OPEN OPEN S RoHS a b c d e i Wireless Alarm System Do218 ...

Page 36: ...33 2 About the Mainboard and Connectors a Power LED b Signal LED Fig9 motherboard and connectors diagram a b c d e f g h i j k l m n o p q r s t u v i Wireless Alarm System Do218 ...

Page 37: ... trouble battery trouble and siren trouble k Record LED The LED will light when recording and then off l Outside siren binding post Don t upset cathode and anode m Battery Pack connector Don t upset cathode and anode n Internet connector o Line and Phone for PSTN DTMF and telephone set connectors p Adapter connector 12VDC q USB connector r Auto restore protector s The binding post of outside siren...

Page 38: ...n be programmed and maintained by the computer When user doesn t know how to program and maintain the engineer can help the user by remote support Especially for the quantity installation project it can save installer much time and costs Connect the telephone line DC12V USB port of the computer as following a Indicator A b Indicator B c DC12V input d USB Port e Telephone line a b c d e Fig 10 i Wi...

Page 39: ... Running the Remote Management Program the start interface will come out The software has integrated interface user just needs to choose in the menu when programming The operation is very convenient and easy F Start Interface for Remote Management ig 11 1 3 Login and Operations 1 3 1 Login After starts up the system and click Log in the following windows will come out Fig 12 i Wireless Alarm Syste...

Page 40: ...s Fig 13 Confirm Fig Login Success 13 F Login window ig 12 Both of the default user name and password are admin The passport can be changed after log in During the operation of remote management firstly should set computer s COM number and calling number as following 1 3 2Communication Port Settings i Wireless Alarm System Do218 ...

Page 41: ...computer the telephone number used for user s control panel iDo218 When finish setting it will display Communication Port successful on the PC FIG 15 Fig 15 Select the communications port success Click Configuration communication port settings and select the COM it will display as following Figure 14 i Wireless Alarm System Do218 ...

Page 42: ...Configuration Communication Port Settings Start Communication Port iDo218UD will dial the control panel The windows will display successful dialing up as shown in Figure 16 Fig 16 Communications port open success 1 3 4 Download data from Control Panel Click Configuration Download upload it will display as Figure 17 Fig 17 Download Upload Window i Wireless Alarm System Do218 ...

Page 43: ...om the iDo218 As Figure 18 40 F Programmed Information ig 18 After download the windows whether reset the iDo218CN If need to continue please click the No Otherwise If you click Yes iDo218UD will stop the dial and set Remote Management Switch Off As Figure 19 Fig 1 Finish Download 9 i Wireless Alarm System Do218 ...

Page 44: ...atus doorbell status code settings phone number partition number and othesr Figure 20 1 3 6 Upload data to Control Panel Select the configuration column as shown in Figure 16 After correct all of data in the iDo218 click the Send to finish upload and setting Such as Click Configuration On Off Settings windows will show as Figure 21 F Other Setting Window ig 21 i Wireless Alarm System Do218 ...

Page 45: ... setting and switch On Off setting other setting code setting etc After corrected all of the data select the columns need to change and then click Send to upload As Figure 22 After upload the system will remind whether to reset the iDo218CN If need to continue please click No otherwise If click Yes iDo218UD will stop the dialing and set remote management switch Off Fig 22 i Wireless Alarm System D...

Page 46: ...ctor Battery Low Detector Tamper Detector No Contact Follow me Fail Alarm report fail No Events 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Keys Arm Keys Disarm Auto arm Auto disarm Remote Arm Remote Disarm Telephone Arm Telephone Disarm Duress Disarm Wrong code AC Trouble AC Restore Telephone Trouble Telephone Restore Standby Battery Low Standby Battery Restore Build in Siren Trouble Build in...

Page 47: ...ing Detectors Wall Detector Wall mounting Coverage Curtain Detector Ceiling Detector Detection Range 9 7 CornerMounting WallMounting CeilingMounting 1 7 0 8m 8m 8m 8m 12m 8 m 8 m 8 m i Wireless Alarm System Do218 ...

Page 48: ...45 Ceiling Detector Ceiling Detector Detection Range 4m i Wireless Alarm System Do218 ...

Page 49: ...es not the iDo218 alarm A First of all check the zone type If it is a close zone then it is disarmed in any status if it is stay arm zone then it is also disarmed status even the stay arm zone has been armed Secondly check if all the partition which belongs to the zone has been armed Thirdly if the zone is set as Correlative Zone Only when the situation is matched the correlative alarm condition a...

Page 50: ...ne Setting of the Main menu there are 0 1 2 3 and 4 five partitions setting options If user wants the iDo218 sends alarm information to CMS then needs to set the relevant partition For example if a detector in Zone 01 needs to send alarm information to the CMS then the user need to set a 4 digits code for Partition 1 With wrong format the alarm information will cannot be recognized by CMS For the ...