Quick Start Guide and Safety Manual
P/N 702195-QUICKSTART – Rev (-)
6
Quick Start Guide and Safety Manual
P/N 702195-QUICKSTART – Rev (-)
3
S
TEP
2
:
C
ONNECT THE
P
OWER
M
ODULE
S
TEP
1
:
M
OUNT THE
D
ATA-LOGGER
Power Module (RCS P/N 748400) is intrinsically safe and may be connected/disconnected
in a hazardous location.
The Microcor
®
Data-Logger can be installed on the top, side or bottom of the line according
to the probe installation. Choose the best installation configuration that corresponds to the
location of the probe.
Grounding
*INTRINSICALLY SAFE
BATTERY PACK
A 8 to 14 AWG grounding wire can be attached to the data-logger at the grounding lug.
Connect the ground wire to earth ground per local electrical code.
COVER
Direct Probe Mounting
PROBE
CONNECTOR
*BATTERY CAN ONLY
BE INSTALLED IN
ONE DIRECTION
Top of the Line
1.
Attach connector and tighten connector nut to mount the data-logger to the probe
adapter.
MAIN HOUSING
PROBE ASSEMBLY
PROBE ADAPTER
DATA PORT
DATA PORT
DATA-LOGGER MOUNTED ON A
COSASCO ACCESS FITTING WITH
RETRIEVABLE PROBE
PROBE ASSEMBLY
COSASCO ACCESS
FITTING WITH PLUG
ASSEMBLY
ACCESS VALVE
RETRACTABLE PROBE
ASSEMBLY WITH
SAFETY CLAMP
DATA-LOGGER WITH A
RETRACTABLE PROBE
ASSEMBLY
S
TEP
3
:
C
ONFIGURE THE
D
ATA-LOGGER
To configure the data-logger, connect the handheld device to the data-logger through the
data port. Refer to the MWT-3905-MDL Reference Manual to set Data-Logger
configurations. Alternatively, the computer software may be used to configure the Data-
Logger.
PROBE ASSEMBLY
Configuration for hazardous/non-hazardous locations
(computer software may only be used in a non-hazardous location).