8 | Storage
42 / 43
KZS-P_KZS-PG
8
Storage
If the centric clamp is not in use, the centric clamp is to be stored in a dry,
protected place in accordance with the storage temperature (environmental
and operational conditions).
9
Troubleshooting
Fault
Possible cause
Measure
The centric clamp does
not go into clamping pos-
ition.
Leakage on a pneumatic
line
Check pneumatic line.
The measured clamping
force decreases from
measurement to meas-
urement.
Insufficient lubrication.
Lubricate the centric
clamp.
Internal soiling.
Complete cleaning (see
).
Defective seals.
Replace seals (see re-
placement of wear parts
in
).