2/13
Application Note
BD93F10MWV Function Description
© 2021 ROHM Co., Ltd.
No. 64AN078E Rev.002
Nov.2021
[Protection Function specification]
●
VBUS Over Voltage Protection : Enabled (Auto Recovery)
●
VBUS Short Circuit Protection : Disabled
●
CC Over Voltage Protection : Enabled (Auto Recovery)
●
VBUS Over Current Protection : Optional (Auto Recovery)
●
Over Temperature Protection (external thermistor)
: Optional (Auto Recovery)
●
Over Temperature Protection (internal temperature
of this product) : Enabled (Auto Recovery)
[Host IF Function specification]
The product is on stand-alone and does not use this function.
[GPIO Function specification]
The following functions are assigned to GPIO.
Table 1. GPIO Function
Terminal#
Name
I/O
Function
21
GPIO0/MSDA
-
(Unused : Hi-Z)
22
GPIO1/MSCL
-
(Unused : Hi-Z)
23
GPIO2
N-OD
ALERT#
24
GPIO3
I
VMAX
25
GPIO4
I
STOPENB
26
GPIO5
O
ORIENT
27
GPIO6
I
VMIN
28
GPIO7
I
PMIN
29
GPIO8/SDA1
I
ORIENT
30
GPIO9/SCL1
O
VBRDY
“
O
”:
VDDIO Level Output
“
N-OD
”:
Nch Open Drain Output
Unused terminal is Hi-Z. Please use Open or Pull down to GND.