User’s Guide
BD93E11GWL-EVK-001 (Stand-Alone)
(Change configuration of the PD contracts)
Note: The configurations of SW_VMAX, SW_VMIN, and SW_PMIN are stored upon power up.
Dynamically changing the DIP
switches will not change the configuration during operation.
Please do the following procedures to set the new configuration.
Settings will be reflected after a power cycle of the EVK.
1.
Turn off VSRC5V if powered up.
2.
Unplug the Type-C cable from the Type-C Receptacle and disconnect it from the Source device.
3.
Change SW_VMAX, SW_VMIN, and SW_PMIN according to the requirement.
4.
Power up VSRC5V if necessary. The new configuration is stored at power up.
5.
Reconnect the Source device to the Type-C receptacle of the EVK via the Type-C cable.