![Rohde & Schwarz ZNL Series User Manual Download Page 162](http://html.mh-extra.com/html/rohde-and-schwarz/znl-series/znl-series_user-manual_1477893162.webp)
Remote Commands to Perform Measurements with I/Q Data
R&S
®
ZNL
162
User Manual 1178.5989.02 ─ 06
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
TRAC:IQ ON
Switches on acquisition of I/Q data.
TRAC:IQ:AVER ON
Enables averaging of the I/Q measurement data.
TRAC:IQ:AVER:COUN 10
Selects averaging over 10 data sets.
TRAC:IQ:DATA?
Starts the measurement and reads out the averaged data.
9.7.2
Configuring Spectrograms
In addition to the standard "level versus frequency" or "level versus time" spectrum
traces, the R&S
ZNL also provides a spectrogram display of the measured data. A
spectrogram shows how the spectral density of a signal varies over time. The x-axis
shows the frequency, the y-axis shows the time. The commands required to configure
spectrograms in a remote environment are described here. For details and manual
operation see
Chapter 6.2, "Spectrogram Settings"
When configuring spectrograms, the window suffix is irrelevant. The settings are
always applied to the spectrogram window, or to all spectrogram windows, if several
are active for the same channel setup.
For commands to set markers in spectrograms, see
Chapter 9.7.3.4, "Marker Search
9.7.2.1
9.7.2.2
9.7.2.1
Configuring a Spectrogram Measurement
CALCulate<n>:SGRam:CLEar[:IMMediate]
.......................................................................163
CALCulate<n>:SPECtrogram:CLEar[:IMMediate]
.............................................................. 163
............................................................................... 163
CALCulate<n>:SPECtrogram:CONTinuous
.......................................................................163
CALCulate<n>:SGRam:FRAMe:COUNt
........................................................................... 164
CALCulate<n>:SPECtrogram:FRAMe:COUNt
...................................................................164
CALCulate<n>:SGRam:FRAMe:SELect
........................................................................... 164
CALCulate<n>:SPECtrogram:FRAMe:SELect
...................................................................164
...................................................................................... 164
CALCulate<n>:SPECtrogram:HDEPth
..............................................................................164
........................................................................................165
CALCulate<n>:SPECtrogram:LAYout
............................................................................... 165
.......................................................................................165
I/Q Analysis