![Rohde & Schwarz TS-PWA3 User Manual Download Page 67](http://html1.mh-extra.com/html/rohde-and-schwarz/ts-pwa3/ts-pwa3_user-manual_1477884067.webp)
Plug-In Modules
R&S
®
TS-PWA3
51
User Manual 1157.8143.12 ─ 17
With adapters, you should remember that the count sequence on connector P20 at the
back of the control backplane is the mirror image of the front.
The plug-in modules used in the R&S TS-PWA3 are described in separate documents.
7.2
Configuration Instructions
●
Care must be taken to observe EMC regulations. Sufficient shielding can only be
achieved with sectional front plates and shield springs on the inner and outer fas-
tening level. The two levels can be connected with option R&S TS-PSK1 (HF
shield wall kit). One slot is lost in this process.
●
If long cards are plugged in next to short ones, care must be taken to ensure the
sectional front plate of the short card cannot touch the lines of the adjacent module
(risk of short circuit).
●
To achieve even dissipation of heat, modules with R&S TS-PDC should not be fit-
ted immediately next to each other if possible. This makes it easier to cool the R&S
TS-PDCs, which can become quite hot. The optionally available rear I/O fan unit
R&S TS-RFAN provides for enhanced cooling of the R&S TS-PDC and is required
especially when the installation position is not horizontal.
●
R&S TS-PSM1, R&S TS-PSM3, R&S TS-PSM4, and R&S TS-PSM5 should be
connected to slot 16 so that signals from the power plug can be better directed to
the back.
For this purpose, the optional cabling kit R&S TS-PK04P (No. 1157.9104.03) can
be used.
If an additional R&S TS-PSM1 or R&S TS-PSM4 is required, it should be connec-
ted to slot 15.
For more details, refer to the documentation of the individual modules.
Configuration Instructions