Parameters:
<State>
1 | ON | 0 | OFF
*RST:
0
Example:
See
Example "Distributing the I/Q streams to the output connec-
Manual operation:
See
:SCONfiguration:OUTPut:MAPPing:STReam<st>:FOFFset
<SmFreqOffset>
Sets an absolute frequency offset.
Parameters:
<SmFreqOffset>
float
Range:
depends on the installed options, e.g. -60E6 to
+60E6 (base unit)
Increment: 0.01
*RST:
0
Example:
See
Example "Distributing the I/Q streams to the output connec-
:SCONfiguration:OUTPut:MAPPing:STReam<st>:POFFset
<SmPhasOffset>
Sets the phase offset of the corresponding stream.
Parameters:
<SmPhasOffset>
float
Range:
-999.99 to 999.99
Increment: 0.01
*RST:
0
Example:
See
Example "Distributing the I/Q streams to the output connec-
13.15.3
External RF and I/Q instruments
The following commands configure external RF and I/Q instruments.
Commands:
:SCONfiguration:EXTernal:DISPlay
.................................................................................. 720
:SCONfiguration:EXTernal:ACONnect
.............................................................................. 720
:SCONfiguration:EXTernal:REMote:CONNect[:ALL]
...........................................................720
:SCONfiguration:EXTernal:REMote:DISConnect[:ALL]
....................................................... 720
:SCONfiguration:EXTernal:PBEHaviour
............................................................................ 721
:SCONfiguration:EXTernal:CODer<ch>:DIRection?
............................................................721
:SCONfiguration:EXTernal:FADer<ch>:DIRection?
............................................................ 721
:SCONfiguration:EXTernal:RF<ch>:DIRection?
................................................................. 721
:SCONfiguration:EXTernal:IQOutput<ch>:DIRection?
........................................................ 721
SCONfiguration subsystem