Multi-instrument setups
R&S
®
SMM100A
479
User Manual 1179.1341.02 ─ 05
Remote command:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:PRESet
Save/Recall
Accesses the "Save/Recall" dialog, that is the standard instrument function for saving
and recalling the complete dialog-related settings in a file. The provided navigation
possibilities in the dialog are self-explanatory.
The settings are saved in a file with predefined extension. You can define the filename
and the directory, in that you want to save the file.
See also
Chapter 10, "File and data management"
Remote command:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:CATalog?
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:STORe
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:LOAD
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:DELete
RF Envelope
In instruments equipped with option R&S
SMM100A-K540, enables the output of a
control signal that follows the RF envelope. This control signal is provided for power
amplifiers envelope tracking testing. The signal is output at the I/I Bar connectors.
The envelope tracking (ET) is a method used by modern power amplifiers (PA) to
improve their efficiency, especially when amplifying high crest factor RF signals. With
envelope tracking, the PA estimates, i.e. "tracks", the RF signal and varies the supply
voltage at the end amplifying stage synchronous to the changes in the RF signal.
See user manual R&S
SMM-K540, R&S
SMM-K541 Envelope Tracking and AM/AM,
AM/PM Predistortion.
Remote command:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:ENVelope:STATe
Show Connector
Accesses a dialog that displays the physical location of the selected connector on the
front/rear panel of the instrument.
A blinking LED on the front/rear panel indicates the selected connector, too (see
ter 11.2.2.4, "Status indicators"
I/Q Output Type
Selects the type of output signal.
The provided parameters in the "I/Q Analog Outputs" dialog depend on the selected
output mode.
"Single-Ended"
●
If "RF Envelope > Off"
Single-ended output at the I/Q connectors.
●
If "RF Envelope > On"
The envelope signal E is output at the I connectors.
You can define a bias between the output signal and ground.
I/Q analog output settings