Command Reference
R&S
®
CMW-KM750/-KM751
96
User Manual 1173.9670.02 ─ 05
Parameters:
<MagErrRMS>
Range:
0 % to 20 %
*RST:
17.5 %
Default unit: %
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
<MagErrPeak>
Range:
-20 % to 20 %
*RST:
17.5 %
Default unit: %
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.2.7
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:EVMagnitude
<EVMRMS>,
<EVMPeak>
Defines upper limits for the RMS and peak values of the error vector magnitude (EVM).
Parameters:
<EVMRMS>
Range:
0 % to 20 %
*RST:
17.5 %
Default unit: %
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
<EVMPeak>
Range:
0 % to 20 %
*RST:
17.5 %
Default unit: %
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.2.7
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:PERRor
<PhaErrRMS>,
<PhaErrPeak>
Defines a symmetric limit for the RMS and peak values of the phase error. The limit check
fails if the absolute value of the measured phase error exceeds the specified value.
Parameters:
<PhaErrRMS>
Range:
0 deg to 20 deg
*RST:
10 deg
Default unit: deg
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Multi Evaluation Measurement Commands