Command Reference
R&S
®
CMW-KM750/-KM751
77
User Manual 1173.9670.02 ─ 05
<ModScalarEnable> OFF | ON
Modulation Scalar Results
*RST:
ON
<BEREnable>
OFF | ON
Bit Error Rate
*RST:
OFF
Firmware/Software:
V1.0.2.7
V1.0.5.3: <BEREnable>
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:MEValuation:RESult
<ResEnable>
Enables or disables the evaluation of all results and shows or hides the views in the multi
evaluation measurement.
Setting parameters:
<ResEnable>
OFF | ON
ON
: Evaluate all results and show all views
OFF
: Do not evaluate any results, hide all views
Return values:
<ResEnable>
OFF | ON
A list of states is returned, corresponding to the values returned
by
Example:
See
Performing Single-Shot Measurements
Firmware/Software:
V1.0.2.7
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:MEValuation:RESult:EVMagnitude
<EVMEnable>
Enables or disables the evaluation of results and shows or hides the error vector mag-
nitude view in the multi evaluation measurement.
Parameters:
<EVMEnable>
OFF | ON
OFF:
Do not evaluate results, hide the view
ON:
Evaluate results and show the view
*RST:
ON
Firmware/Software:
V1.0.2.7
Manual operation:
See