Remote-control commands
DVB-H
59
Operating Manual 1008.0970.12 ─ 16
The unit is defined with command
SOUR:BB:DVB:TRIG:SLUNit
. It is then possible to
output deliberately just part of the frame, an exact sequence of the frame, or a defined
number of repetitions of the frame.
Parameters:
<SLength>
integer
Range:
1 to 7000
*RST:
4
Example:
BB:DVB:SEQ SING
sets trigger mode Single.
BB:DVB:TRIG:SLUN FRAM
sets unit frames for the entry of sequence length.
BB:DVB:TRIG:SLEN 200
sets a sequence length of 200 frames. The current frame will be
output 200 times after the next trigger event.
Manual operation:
See
[:SOURce<hw>]:BB:DVB:TRIGger:SOURce
<Source>
Selects the trigger source.
Parameters:
<Source>
INTernal|OBASeband|BEXTernal|EXTernal
INTernal
manual trigger or
*TRG
.
EXTernal|BEXTernal
trigger signal on the TRIGGER 1/2 connector.
OBASeband
trigger signal from the other path
*RST:
INTernal
Example:
SOURce1:BB:DVB:TRIGger:SOURce EXTernal
sets external triggering via the TRIGGER 1 connector.
Manual operation:
See
[:SOURce<hw>]:BB:DVB:TRIGger[:EXTernal<ch>]:DELay
<Delay>
Specifies the trigger delay (expressed as a number of samples) for external triggering.
The numeric suffix to EXTernal distinguishes between the external trigger via the
TRIGGER 1 (suffix 1) and TRIGGER 2 (suffix 2) connector.
Parameters:
<Delay>
float
Range:
0 to 65535
Increment: 0.01
*RST:
0
Default unit: Sample