Remote Commands
R&S
®
Spectrum Rider FPH
359
User Manual 1321.1011.02 ─ 11
Parameters:
<Threshold>
Numeric value whose unit depends on the unit you have cur-
rently selected for the vertical axis.
Default unit: dBm
Example:
CALC:LIM1:UPP:THR -10DBM
Defines a threshold of -10 dBm.
13.6.2.9
Configuring and Using Measurement Functions
The R&S Spectrum Rider provides measurement functions that allow you to perform
advanced measurements and can also be controlled remotely.
..................................................................................359
........................................................................................... 361
..............................................................................365
...............................................................................................367
Measuring the Occupied Bandwidth
..................................................................... 369
........................................................................................... 370
Measuring the Adjacent Channel Leakage Ratio
..................................................371
Measuring the Harmonic Distortion
.......................................................................382
Measuring the AM Modulation Depth
....................................................................384
Measuring the Spectrum Emission Mask
..............................................................385
...................................................................................386
Configuring Channel Tables
The following commands configure the channel tables.
List of commands
............................................................................................... 359
[SENSe:]CHANnel:TABLe:SELect<1...4>
......................................................................... 360
[SENSe:]CHANnel:TABLe:SELect:DOWNlink
....................................................................360
[SENSe:]CHANnel:TABLe:SELect:UPLink
........................................................................ 361
........................................................................................361
[SENSe:]CHANnel<1...3>
<ChannelNumber>
This command selects the channel to be analyzed.
You have to set the frequency mode with
The numeric suffix at CHANnel is irrelevant for this command.
Parameters:
<ChannelNumber>
Numeric value that selects the number of the channel to be ana-
lyzed.
*RST:
Depends on the channel table.
Example:
See
[SENSe:]CHANnel:TABLe:SELect<1...4>
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH