CALCulate<1...2>:MARKer<1...6>:FUNCtion:MDEPth[:STATe]
<State>
This command turns the AM Modulation Depth measurement on and off.
The suffix at CALCulate and MARKer are irrelevant for this command.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:MARK:FUNC:MDEP ON
Activates the AM modulation depth measurement.
CALCulate<1...2>:MARKer<1...6>:FUNCtion:MDEPth:RESult?
This command queries the results of the AM modulation depth measurement.
The suffix at CALCulate and MARKer are irrelevant for this command.
Parameters:
<Return values>
<ModulationDepth>
Modulation depth in %.
Example:
CALC:MARK:FUNC:MDEP:RES?
Queries the AM modulation depth.
Usage:
Query only
Measuring the Spectrum Emission Mask
The following commands configure Spectrum Emission Mask (SEM) measurements..
To perform the actual measurement, use the commands described in section
ter 13.6.2.5, "Performing and Triggering Measurements"
List of commands
CALCulate<1...2>:MARKer<1...6>:FUNCtion:TXPower:RESult?
......................................... 385
[SENSe:]ESPectrum:PRESet[:STANdard]
.........................................................................386
[SENSe:]ESPectrum:PRESet:SETTings
........................................................................... 386
CALCulate<1...2>:MARKer<1...6>:FUNCtion:TXPower:RESult?
This command queries the total TX channel power. Use
MARKer<1...6>:FUNCtion:POWer:RESult?
on page 364 to query the power of
each TX channel.
The suffix at CALCulate and MARKer are irrelevant for this command.
Parameters:
<Return values>
<Power>
The power is either the peak power or the channel power,
depending on the selected standard.
Remote Control - Commands