 Testing the Sensor

To put the sensor in test mode, temporarily separate the base from the cover as outlined 
under “Mounting the Sensor”. Replace the cover and ensure it is secure. The detector 
enters a stabilization or warm-up mode for 20 seconds during which time, the LED will flash 
Red followed by the network status.

The network status indications are outlined below:

The sensor is now in test mode for 15 minutes. Perform a low frequency test by thumping 
the protected glass with a cushioned object. If the test is successful, the LED will light 
orange for 2 seconds followed by the network status as outlined above. Repeat the test if 
necessary. If repeated tests fail, the sensor may need to be moved to a more suitable 
location as outlined in section “Finding a Suitable Location”.

Full light indications are outlined below:

Note: 

In test mode the detector is more sensitive and will react to audio noises such as 

hand clapping or knocking on adjacent walls. Sounds of this type will not trigger detection 
after the test mode ends.