background image

MCX402DR Operating Manual.doc 

  

2018-09-03 

 

10/11 

 

 

Fig. 9 MCX402DR board 
 

MCX402DR terminals 

Term. 

Description 

Term. 

Description 

BAT+ 

Battery positive pole 

GND 

Ground 

BAT- 

Battery negative pole 

IN7 

IN7 input line 

P1 

Power supply input 

IN8 

IN8 input line 

P2 

Power supply input 

IO1 

IO1 output line 

COM1 

REL1 relay common terminal 

IO2 

IO2 output line 

NC1 

REL1 relay output (NC) 

IN1 

IN1 input line 

NO1 

REL1 relay output (NO) 

IN2 

IN2 input line 

CLK 

RACS CLK/DTA interface, line CLK 

GND 

Ground 

DTA 

RACS CLK/DTA interface, line DTA 

IN3 

IN3 input line 

GND 

Ground 

IN4 

IN4 input line 

RS485 communication bus, line A 

TML 

Power supply output 12VDC/0.2A 

RS485 communication bus, line B 

AUX 

Power supply output 12VDC/1.0A 

GND 

Ground 

NO2 

REL2 relay output (NO) 

IN5 

IN5 input line 

NC2 

REL2 relay output (NC) 

IN6 

IN6 input line 

COM2 

REL2 relay common terminal 

 

Specification 

Supply voltage 

Nominal 18VAC, min./max. range 17-22VAC 

Nominal 12VDC, min./max. range 10-15VDC 

Nominal 24VDC, min./max. range 22-26VDC 

Backup battery 

13.8V/7Ah, charging current app. 300mA  

Average current 
consumption 

100 mA (excluding load points connected to AUX and/or TML outputs) 

Summary of Contents for MCX402DR-BRD

Page 1: ...Roger Access Control System MCX402DR BRD I O expander Operating Manual Product version 1 0 Firmware version 1 0 2 255 Document version Rev B...

Page 2: ...ery The expander is offered individually as electronic module or as a component of MCX402 1 KIT for read in out door control or as a component of MCX402 2 KIT for two read in doors control In case of...

Page 3: ...from 230VAC 18VAC 40VA transformer and then it offers 13 8VDC power outputs AUX TML for external devices Optionally the expander can be supplied from 12VDC or 24VDC but in case of 12VDC the backup ba...

Page 4: ...mal state and is shorted to ground when triggered Output with reversed polarity operates with inverted logic It is shorted to ground in normal state and represents high impedance when triggered The co...

Page 5: ...ad in read out door with PRT readers A and Wiegand readers B Connection of expander to controller The expander is not operated as standalone device but as an extension of MC16 access controller It is...

Page 6: ...erVDM software address The factory new expander has ID 100 software address Addressing with jumpers Every time the address is modified the expander must be restarted with RST button or switching power...

Page 7: ...its every pressed key separately Range Yes No Default value Yes Min PIN length Parameter defines minimal number of digits in PIN Range 0 8 When set to 0 then PIN is disabled Default value 4 Max PIN le...

Page 8: ...ment Parameter defines any text or comment which corresponds to the object It is later displayed in VISO program CDI comment as above Card code length Parameter defines type of Wiegand 26 66bit interf...

Page 9: ...RT readers then another firmware must be uploaded Such firmware is available at www roger pl Firmware update is also used in case of migration from RACS 4 to RACS 5 when PR411 and PR402 controllers ar...

Page 10: ...ne CLK GND Ground DTA RACS CLK DTA interface line DTA IN3 IN3 input line GND Ground IN4 IN4 input line A RS485 communication bus line A TML Power supply output 12VDC 0 2A B RS485 communication bus lin...

Page 11: ...RD I O expander for door control with Wiegand or PRT readers MCX402 1 KIT 1 door expander kit MCX402 2 KIT 2 door expander kit Product history Version Date Description MCX402DR v1 0 10 2017 The first...