TECHNICAL DETAILS
1 motor 230V~ ±10% 50Hz, 2200W max
Working temperature from -10 to +55°C
Flashing light 1A max (tension free contact )
Courtesy 2A max (tension free contact)
Open gate led 24Vcc 2W max
Accessories current 300mA max on 24Vcc
2 levels of slow-down speed
8 levels of start up torque
8 levels of normal torque on travel
8 levels of force on slow-down
Electronic stop with 8 levels of stopping torque
99 sensibility levels to find an obstacle on normal
speed
99 sensibility levels to find an obstacle on slow-
down speed
Software selection on right or left motor
Software exclusion of input N.C. not used
Configurable input clock
2 inputs for safety edge
1° radio channel used for different input/output
2° radio channel used for different input/output
Flashing light output free of tension
Courtesy light output free of tension
Travel checking by encoder and limit switch
Automatically learning of the travel
Works without limit switch (it is necessary encoder)
5 modes of input functioning of step by step
Password to protect the configuration
Memorized of n° of movement
Memorized working time of the motor
Memorized working time of control unit
Showed serial number of control unit
CONFIGURATION OF THE PARAMETERS
The configuration of the control unit is made changements on
the predefinied value associated on the parameter through 3
buttons, S1, S2 e S3, and it showed on the dispaly (picture 1).
The control unit is supplied with default value, please look on
last columns on the attached parameters table.
STANDBY MODE
After 10 minutes without any pushing, display comes on standby, and it shows You only the POWER segment
with intermittent light (picture 5).
SHOWING INPUT MODE
When the power comes back, or pushing one of the 3 buttons, the display will show You the inputs state.
From each input of the control unit is associated a segment on display (picture 5). If the input is closed the
segment is on, if the input is open the segment is off, if the input is not enable (short circuited) on software the
segment flashing
The 2 radio channels can be associated to different comands (parameters 76 e 77), when we activate one of
the radio channel the control unit will show You the referent segment.
SHOWING PARAMETERS MODE
When we push the buttons S1 or S2, the control unit changes from input showing to parameters showing
(picture 2).
The parameter is showed on the first two numbers on the left of the display by intermittent light, while the value
of the parameter is showed on the right of the display by fixed light.
When we push the button S2 the control unit shows You the next parameter and his value from the first to the
last. By the parameter LL=0 the control unit shows You only the basic parameter, while by LL=1 the control
unit shows You all the parameters.
When we achieve the last parameter (CP), another pushing of the button S2 the control unit will show You the
input showing, and if we push again the button the control unit will show You the parameters showing yet. By
the button S1 we have the same functions but in the opposite way, from the last to the first.
10
INPUT
LL
02
03
...
P4
CP
S2
S2
S2
S2
S2
S2
INPUT
LL
02
03
...
P4
CP
S1
S1
S1
S1
S1
S1
S1
SELECTION BUTTON SCROLLING BUTTON
S3
S2
+
PARAMETER NUMBER PARAMETER VALUE
S1
-
Picture 1
S2
Picture 2
GB