8  Repair and service

 

 

8.1  Check dimension A 

Check proper functioning by using the check 
dimension A in released state.  
When  the  depth  of  A  is  maintained  as 

specified  in  the  table,  the  fast  closing  clamp 
functions properly. 

 

Check dimension A ±0.2 

 

 

If  check  dimension  A  is  exceeded,  an 
authorised 

service 

engineer 

must 

service the part immediately. 

If  servicing  is  not  undertaken,  safe  clamping  of 
the retractable nipple is no longer possible. There 
is a risk of accidents. 
 

 
 
 

Monthly: 

Verify check dimension 
with clamping element 
released. There is a 
check dimension tester 

to measure the check dimension of every size. 
The tester can be procured from Stark 
Spannsysteme GmbH 

Order No. 504 022, 504 029  

 

 
 

 

Annually or after 5000 clamping cycles: 

Measure insertion force of fast closing clamp. 
To measure the insertion force, order a suitable 
mechanical tensile force tester (Order No. 504 
000) from Stark Spannsysteme GmbH. 
 

8.2  Surface cleaning 

 

 

Correct! 

The fast closing clamp may be blown out 

and off using compressed air. 

 

 

Correct and better!

 

Vacuum clean to remove swarf, dirt and 
coolant from the fast closing clamp. 

 

In principle, there should be no soiling 
inside the fast closing clamp. Clean 
depending on the application and change 

interval. Pay attention to max. clamping cycles. 
When servicing date is reached: only allow 
suitably instructed personnel to perform 
servicing. 

Summary of Contents for WM-020-369-10-en BA

Page 1: ...mping system Operating Manual WM 020 369 10 en BA SPEEDY classic 2 balance Manufacturer STARK Spannsysteme GmbH Roemergrund 14 6830 Rankweil Austria Tel 43 0 55 22 37400 0 Fax 43 0 55 22 37400 700 E m...

Page 2: ...ast closing clamp plate 5 4 7 3 Malfunction in the hydraulic system During operation 5 4 7 4 Hazard due to incorrect mounting of the fast closing clamp 6 4 7 5 Hazard due to changes in peripheral spee...

Page 3: ...intenance of the fast closing clamping device provide important information on the safe and efficient use of the fast closing clamping device 3 2 Presentation of safety instructions Safety instruction...

Page 4: ...fications defined for normal operation Using as lifting gear and for transporting loads The operator owner bears the sole responsibility for damage due to improper use The manufacturer will not accept...

Page 5: ...energy on the fast closing clamping device as well as pressure in cylinders and valves after switching off the fast closing clamping device 4 7 1 Spring assembly If the fast closing clamp is dismounte...

Page 6: ...ipheral speed The fast closing clamp may fracture due to excessive speed excess weight or imbalance and the pallet thrown off Action Comply with specifications and regulations regarding maximum values...

Page 7: ...p While machining is in progress on one pallet another can be set up in parallel 6 Mounting and installation Fitting and removal instructions for Speedy classic 2 balance and Speedy classic 2 balance...

Page 8: ...l cage and retaining ring into the centre bore of the piston 5 Fit the locking ring into the disc groove Make sure that the centring diameter surface is not damaged 6 Tighten fast closing clamp to 10...

Page 9: ...password by e mail Training courses Stark Spannsysteme GmbH provides training courses to train your operators and service personnel Training courses are held on site or at Stark Spannsysteme GmbH Plea...

Page 10: ...tening torque connect the hydraulic pressure generator to the circuit Release Slowly and carefully increase the hydraulic pressure to the release pressure During this process check the clamping elemen...

Page 11: ...Verify check dimension with clamping element released There is a check dimension tester to measure the check dimension of every size The tester can be procured from Stark Spannsysteme GmbH Order No 50...

Page 12: ...must be removed for the cleaning Procedure for cleaning 1 Remove locking ring 2 Carefully lift off retaining ring 3 Remove ball cage 4 Remove spring 5 Clean the parts removed incl housing bore check f...

Page 13: ...uct with Corrosive or caustic ingredients or Organic solvents such as halogenated or aromatic hydrocarbons and ketones thinners acetone etc as these substances can irreparably damage the seals The ele...

Page 14: ...guidelines 9 Specifications SPEEDY classic 2 balance Part number 801 201 801 215 Drawing number 069 xxx Description SPEEDY classic 2 balance Check dimension 24 0 2 Lift clearance 1 3 mm Repeatability...

Page 15: ...ing cycles increases 2 Lifting force 10 kN at release pressure 70 bar lifting force 15 kN at release pressure 80 bar 3 Set overpressure safety valve to max 5 bar above the max operating pressure 4 Onl...

Page 16: ...rds auf das sich diese Erkl rung bezieht mit den folgenden Normen bereinstimmt 2006 42 EG Machines addendum II A Maschinen Anhang II A and the following standards were applied und dass die folgenden N...

Reviews: