8 Repair and service
8.1 Check dimension A
Check proper functioning by using the check
dimension A in released state.
When the depth of A is maintained as
specified in the table, the fast closing clamp
functions properly.
Check dimension A ±0.2
If check dimension A is exceeded, an
authorised
service
engineer
must
service the part immediately.
If servicing is not undertaken, safe clamping of
the retractable nipple is no longer possible. There
is a risk of accidents.
Monthly:
Verify check dimension
with clamping element
released. There is a
check dimension tester
to measure the check dimension of every size.
The tester can be procured from Stark
Spannsysteme GmbH
Order No. 504 022, 504 029
Annually or after 5000 clamping cycles:
Measure insertion force of fast closing clamp.
To measure the insertion force, order a suitable
mechanical tensile force tester (Order No. 504
000) from Stark Spannsysteme GmbH.
8.2 Surface cleaning
Correct!
The fast closing clamp may be blown out
and off using compressed air.
Correct and better!
Vacuum clean to remove swarf, dirt and
coolant from the fast closing clamp.
In principle, there should be no soiling
inside the fast closing clamp. Clean
depending on the application and change
interval. Pay attention to max. clamping cycles.
When servicing date is reached: only allow
suitably instructed personnel to perform
servicing.