background image

MODEL  FC-108H-PLC 

Plus

Plus

Plus

Plus

P/N 121-700

Input: 240 VAC

50/60 HZ.

Output: 0-240 VAC

Triple Unit Fuse Size:

Unit A 8 AMPS, Unit B 15AMPS and

Unit C 8 AMPS

80% Duty Cycle at Rated AMPS

© 2000 

RODIX 

RODIX 

RODIX 

RODIX 

INC

INC

INC

INC

....

UNIT A, B AND C

Model FC-108H Plus is a triple control.  Each Unit
is based on the FC-40 Plus Series Feeder Cube

1.  SELECTING 60 OR 120 PULSE

OPERATION

A.   For 60 pulse output - Set switch (S1) to 60 on

"master control" P.C. card (No. 24-489). 

B.   For 120 pulse output - Set switch (S1) to 120

on "master control" P.C. card.

Note:  Readjust MAX pot after changing pulse
switch setting.

2.  LIMITING THE MAXIMUM

OUTPUT OF CONTROL

Adjust the 

MAX

 Output trimpot so that the output

to the feeder reaches its desired maximum level
when the 

MAIN CONTROL DIAL

 is turned fully

clockwise.  The 

MAX

 Output trimpot should be

adjusted to keep the vibratory feeder from
hammering when the control is turned up to full
power.

NOTE:  Output to feeder must be connected
and the control set for proper output frequency
(60 or 120 pulse) setting.  The Run Jumper
must be connected as shown on the wiring
diagram.

A.  Power input should be

 OFF

 or disconnected.

B. Rotate

 MAIN CONTROL DIAL

 on front cover

to 0 or its minimum setting.

C. Open cover to allow access to printed circuit

card.

D. Using 

CAUTION

, turn power 

ON

 (no output

should be present).

E.  Rotate the 

MAIN CONTROL DIAL

 on front

cover slowly to its highest setting.

F.     Adjust  the 

MAX

 Output trimpot so that the

output to the feeder reaches its desired
maximum level when the 

MAIN CONTROL

DIAL

 is turned fully clockwise.  Turning the

MAX

 Output trimpot clockwise increases the

maximum output level.

3.  REMOTE OFF/ON CONTROL

Note: a Run Jumper has been installed at the
factory as shown on the enclosed wiring diagram.

Remote OFF/ON operation of the FC-40 

Plus

Plus

Plus

Plus

Series

Series

Series

Series

  Feeder Cube

®

 control can be configured

to operate in one of the following ways.

A.  A low current switch such as a paddle switch

can replace the factory-installed Run jumper
"J1."  The "Run Contact" connects to
terminals 6 and 7. The contact must be able
to switch 5VDC and 2mA.  The control will
then run only when the contact is closed. 
Refer to Section A of the OFF/ON CONTROL
GUIDE.

B. Feeder Bowl/Hopper Interlock allows the

Hopper control to operate only when the Bowl
is running and the paddle switch contact is
closed. The 

interlock input

 on terminals 11

and 12 of TB2 is controlled by the 

interlock

output

 of a "Parts Sensing Feeder Bowl

Control" such as an FC-90 

Plus

Plus

Plus

Plus

.

Remove jumper "J1" of this control from
terminals 6 and 7.  Connect the Hopper
Paddle switch to alternate terminals 5 and 6.
Connect TB2 terminals 11 and 12 of this
control to the "Parts Sensing Control".  Refer
to Section B of the OFF/ON CONTROL
GUIDE. Check specific instructions for the
"Parts Sensing Control" wiring.  

Note: Only use the Bowl/Hopper Interlock with
a FC-90 and FC-40 Series control.  Two FC-
40 Series controls will not interlock to each
other since neither one has an 

interlock

output

.

FC-108H-PLC APP 2/28/2000

RODIX INC.

FEEDER CUBE
FC-100 

Plus Series

Plus Series

Plus Series

Plus Series

OIL RESISTANT

ADJUSTMENTS AND

SET UP